Test Drive carrier katalog | Page 90

Air-to-Water Heat Pumps Heating Reversible Options • Air heat exchanger with pre-treated fins • Very low noise level • Low leaving water temperature • Very low leaving water temperature • Winter operation in cooling mode • Soft starter (30RQS 039-080) • Partial heat reclaim • Frost protection down to -20°C • High- and low-pressure single and dual-pump hydronic modules with or without expansion tank • High-pressure variable-speed singleor dual-pump hydronic modules with or without expansion tank • JBus, BacNet and LonTalk gateways • Screw or welded water heat exchanger connection sleeves • Master/slave operation • Remote interface \\MAINMENU\STATUS CAPB_T DEM_LIM SP CTRL_PNT EMSTOP 0 100 4.2 -28.9 dsable % % °C °C Circuit B Total Capacity START/STOP ENTER PRO-DIALOG+ Pro-Dialog+ operator interface 30RQS Features • Twelve sizes with nominal cooling capacities from 38 to 149 kW and nominal heating capacities from 42 to 158 kW. • Aquasnap heat pumps for commercial or industrial applications. • Increased energy efficiency at part load - Eurovent energy efficiency class C and D (in accordance with EN14511-3:2013) in cooling mode and B and C in heating mode. • Integrates the latest technologi­ al innovations: ozone-friendly refrigerant c R-410A, scroll compressors, low-noise fans made of a composite material, autoadaptive microprocessor control, electronic expansion valve and variablespeed pump (option). • Low-noise scroll compressors with low vibration level. • Vertical air heat exchanger coils with protection grilles on anti-vibration mountings. • Low-noise Flying Bird IV fans, made of a composite material. Rigid fan installation for reduced start-up noise. • Small unit footprint and a low height (1330 mm), enclosed by easily removable panels. • Simplified electrical connections. • Systematic operation test before shipment and quick-test function for stepby-step verification of the instruments, electrical components and motors. • Several compressors connected in parallel. At part load, around 99% of the time, only the compressors that are necessary operate, ensuring increased energy efficiency. • The electronic expansion device (EXV) allows operation at a lower condensing pressure (EER optimisation), and dynamic superheat management optimises the utilisation of the water heat exchanger surface. • Maintenance-free scroll compressors and fast diagnosis of possible incidents and their history via the Pro-Dialog+ control reduce maintenance costs. • Leak-tight refrigerant circuit. • Corrosion resistance tests, accelerated ageing test on compressor piping and fan supports and transport simulation test on a vibrating table in the laboratory. 88