Technical Supplement Guide
 MT-CC-40 / 50 FL / MT-CC-40 / 50 FL OC
 Description Clamp for channel-to-channel or channel-to-girder connections . Material Specifications
 Standard
 1 Grade 1 F y , ksi ( MPa ) F u , ksi ( MPa ) GB / T 700 Q235 B 34.08 ( 235 ) 53.66 ( 370 ) 1 Mechanical properties of GBT / T 700 Grade Q235 B meet or exceed the mechanical properties of ASTM A1011 SS Grade 33 .
 Corrosion Protection
 Electro-Galvanized ( EG ) Hot Dipped Galvanized ( HDG ) MT-CC-40 / 50 FL
 MT-CC-40 / 50 FL OC MT-CC-40 / 50 FL
 Ordering Information
 Description Weight Per Piece lbs ( kg )
 Quantity Piece ( s )
 Item No . MT-CC-40 / 50 FL 0.70 ( 0.32 ) 20 2399667 MT-CC-40 / 50 FL OC 0.70 ( 0.32 ) 20 2399679
 Figure 5 . Strut-to-Strut Connection
 Table 9 . Allowable Strength Design ( ASD ) Load
 Data 1 , 2 , 3 , 4
 F
 x lb ( kN )
 1,010 4.50 )
 1Minimum safety factor , Ω , for tabulated values is 2.6 .
 F y lb ( kN )
 1,686 ( 7.50 )
 2Multiply tabulated values by 1.5 to obtain minimum Load and Resistance Factor Design ( LRFD ) values . 3See Figure 5 [ 8 ] 4Loading in the -Z direction is not recommended .
 F z lb ( kN )
 1,124
 ( 5.00 )
 Table 10 . Limit State Design ( LSD ) Load Data 1 , 2 , 3
 F x lb ( kN )
 1,405 ( 6.26 )
 1Maximum resistance factor , ϕ , for tabulated values is 0.51 . 2See Figure 5 [ 8 ] 3Loading in the -Z direction is not recommended .
 F y lb ( kN )
 2,345 ( 10.43 )
 F z lb ( kN )
 1,560 ( 6.96 )
 See Instructions For Use ( IFU ), packaged with the product , for special installation parameters and additional hardware required . Contact Hilti Technical Services for additional information .
 8