MT Fast-Lock Portfolio Tech Guide Supplement March 2025 | Page 9

Technical Supplement Guide
MT-C-LL2
FL / MT-C-LL2 FL OC
Description 8-hole angle connector for channels . Material Specifications
Standard 1 Grade 1 F y , ksi ( MPa ) F u , ksi ( MPa ) GB / T 700 Q235 B 34.08 ( 235 ) 53.66 ( 370 )
1 Mechanical properties of GB / T 700 Grade Q235 B meet or exceed the mechanical properties of ASTM A1011 SS Grade 33 .
Corrosion Protection
Electro-Galvanized ( EG ) Hot Dipped Galvanized ( HDG ) MT-C-LL2 FL
MT-C-LL2 FL OC MT-C-LL2 FL
Ordering Information
Description Weight Per Piece lbs ( kg )
Quantity Piece ( s )
Item No . MT-C-LL2 FL 1.30 ( 0.59 ) 10 2399661 MT-C-LL2 FL OC 1.30 ( 0.59 ) 10 2399676
Figure 6 . MT Strut Connection
Table 11 . Allowable Strength Design ( ASD ) Load
Data 1 , 2 , 3
F x lb ( kN )
1,025 ( 4.56 )
1Minimum safety factor , Ω , for tabulated values is 2.65 .
F y lb ( kN )
170 ( 0.77 )
2Multiply tabulated values by 1.5 to obtain minimum Load and Resistance Factor Design ( LRFD ) values . 3See Figure 6 [ 9 ]
F z lb ( kN )
1,025 ( 4.56 )
Table 12 . Limit State Design ( LSD ) Load Data 1 , 2
F x lb ( kN )
1,320 5.88
1Maximum resistance factor , ϕ , for tabulated values is 0.5 . 2See Figure 6 [ 9 ]
F y lb ( kN )
210 ( 0.95 )
F z lb ( kN )
1,320 ( 5.88 )
See Instructions For Use ( IFU ), packaged with the product , for special installation parameters and additional hardware required . Contact Hilti Technical Services for additional information .
9