Technical Supplement Guide
MT-C-L2E FL / MT-C-L2E FL OC
Description
3-hole
angle connector for channel-to-channel or channelto-girder .
Material Specifications
Standard 1 Grade 1 F y , ksi ( MPa ) F u , ksi ( MPa ) DIN EN 10025-2 S235JR 34.08 ( 235 ) 52.21 ( 360 )
1 Mechanical properties of DIN EN 10025-2 Grade S235JR meet or exceed the mechanical properties of ASTM A1011 SS Grade 50 .
Corrosion Protection
Electro-Galvanized ( EG ) Hot Dipped Galvanized ( HDG ) MT-C-L2E FL
MT-C-L2E FL OC
MT-C-L2E FL
Ordering Information
Description Weight Per Piece lbs ( kg )
Quantity Piece ( s )
Item No . MT-C-L2E FL 0.57 ( 0.26 ) 20 2399666 MT-C-L2E FL OC 0.57 ( 0.26 ) 20 2399678
Figure 4 . MT Channel Connection Table 7 . Allowable Strength Design ( ASD ) Load Data 1 , 2 , 3
F x lb ( kN )
610 ( 2.71 )
1Minimum safety factor , Ω , for tabulated values is 2.50 .
F y lb ( kN )
350 ( 1.56 )
2Multiply tabulated values by 1.5 to obtain minimum Load and Resistance Factor Design ( LRFD ) values . 3See Figure 4 [ 7 ]
F z lb ( kN )
820 ( 3.65 )
Table 8 . Limit State Design ( LSD ) Load Data 1 , 2
F x lb ( kN )
789 ( 3.51 )
1Maximum resistance factor , ϕ , for tabulated values is 0.52 . 2See Figure 4 [ 7 ]
F y lb ( kN )
490 ( 2.18 )
F z lb ( kN )
1,155 ( 5.14 )
See Instructions For Use ( IFU ), packaged with the product , for special installation parameters and additional hardware required . Contact Hilti Technical Services for additional information .
7