J. Eur. Opt. Society-Rapid Publ. 21, 48( 2025)
Table 2. Comparison between the semi-classical model( SCM), the nonlinear momentum model( NMM), the nonlinear Hamiltonian model( NHM) and the experimental data.
I p [ W cm �2 ]
2.4 10 0
6.6 10 3
5.5 10 8
3.7 10 9
N exp twin [ Hz ] [ present work ]
1: 1 104
4 10 7
3:7 10 14
1:2 10 21
N SCM twin
[ Hz ] [ present work ]
2: 7 103
7:7 10 6
1:3 10 14
2:6 10 20
N NMM twin [ Hz ] [ 9, 10 ] 6:9 10 3 1:7 10 7 1:3 10 12 1:5 10 14
N NHM twin [ Hz ] [ 11 ] 5: 4 103 8:1 10 6 1:0 10 12 1:1 10 14
and the product bL is taken as the relevant parameter for distinguishing the two regimes since this quantity is the argument of the ch and sh functions of equation( 7). Then it comes: 8
>< lim bL1 N twin ¼
>: lim N twin ¼ 1 bL1 4pjajL
2 pv ðÞ 2
eff
2 0 cn s n i n p k 2 s jaj I pL;
exp ð 2bL Þ: ð8Þ
Setting bL = 1 allows us to define the pump intensity
I limit p ð0Þ that delimits the two regimes. According to equation( 5), itwrites:
I lim p ð0Þ ¼ n p
2ji ¼ 30 MW cm �2 ð9Þ
2l 0 cL 2 v ðÞ 2 j s eff
These 30 MW cm �2 are qualitatively close to the 40 MW cm �2 found by extrapolating our experimental results, as shown in Figure 3.
To take one step further, the interpolation of the experimental data with the SCM leads to a full agreement in terms of magnitude and behaviour, as shown in Figure 3( black dotted curve), by taking E vacuum s; i
28 V m �1 which is very close to the calculated value, i. e., 12.7 V m �1. Itisdifficult at this step to find a satisfying explanation for this small discrepancy.
Note that the numerical integration of equation( 3), where there is no approximation regarding the pump depletion, leads to the same curve than that calculated with equation( 7) where the UPA is assumed, which is a validation of equation( 7).
4 Discussion
We performed a comparison between our semiclassical model( SCM) with two reliable quantum models previously developed: The nonlinear momentum model( NMM) summarized in Appendix B describes the quantum field in term of space dependent spectral mode operators a( x, Z) and considers a single collinearly propagating spatial mode [ 10, 11 ]. While the nonlinear Hamiltonian model( NHM) summarized in Appendix C describes the quantum field in term of time dependent mode operators a( t)[ 12 ]. At first, it appears that these two quantum models provide quite indistinguishable behaviors on the graph of Figure 3 but there is a small difference between them considering the
Table 3. Quantification of the error between theory and experiment using the SCM and NMM modelling.
SCM NMM
Low gain D 2
4:8
1.8
High gain D 2
0:026
14
Total D 2
4.8
15.8
corresponding numerical values as can be seen in Table 2. This proximity between the two models is not surprising, given the identical definition of the quantum field. Furthermore, it appears that NMM and NHM are better than SCM in the linear part, contrary to the exponential part, i. e., above 40 MW cm �2, where the agreement of the SCM with the experimental data is much better than for the NMM and NHM. Table 2 gives some numerical values that allows us to directly compare the experimental data with the three models.
There is a discrepancy of a factor of about 3 at 550 MW cm �2 for the SCM while it is two orders of magnitude in the case of the NMM and NHM. And it is a factor 4.6 versus seven orders of magnitude at 3.7 GW cm �2. The difference between experiment and theory is quantized hereafter using the error quantifier v 2 that is the classical error statistical function. Note that we wrote it D 2 in order to avoid any confusion with the second-order electric susceptibility. Its calculation is detailed in Appendix E, and the corresponding numerical values given in Table 3 for SCM and NMM. The better agreement of the SCM at high intensity can be explained by simply considering that in this regime, the generated twin-photons amount is much bigger than the quantum fluctuations of vacuum: from Figure 3 at I lim p, there are N twin = 1.5 10 11 Hz compared to 5.0 10 10 Hz of“ photons of vacuum”. Asaconsequence, this range of intensity mainly corresponds to a coupling between classical fields, which is the framework of equation( 3) coming from Maxwell’ s equations. In other words, the SCM becomes less and less of an approximation as pump intensity increases. It is exactly the reverse for the quantum models NMM and NHM that are a little bit better than the semi-classical model SCM at low pump intensity. Note that the quantum models NMM and NHM can also fit wellthe experimental data with a multiplicative constant c = 3in front of the effective coefficient v ð2Þ eff