JEOS RP ISSN02 | 页面 180

J. Eur. Opt. Society-Rapid Publ. 21, 48( 2025) 175
Fig
. 2. Twin photons spectrum. The dark line is the spectrum obtained when the complete emission cone is collected. The orange line corresponds to the spectrum obtained by diaphragming the non-collinear contributions. On the beam profile in inset, the numerical aperture of the collection lens is drawn as a circle in each case( black and orange circle). The vertical dashed lines correspond to the theoretical expectations.
registered with or without an iris between the crystal output and the spectrometer, in order to diaphragm the profile. The first one, with the iris, in orange on Figure 2, corresponds to the center of the SPDC beam profile spotted by the orange circle in the inset: The signal and idler wavelengths are in good agreement with the theoretical expectation from equations( 1) and( 2), i. e., k s ¼ 1037 nm and k i = 1092 nm( vertical dashed lines). In contrast, the second spectrum( without the iris), in black, corresponding to the full SPDC beam profile, is broaden because of non-collinear contributions.
The selected generated signal and idler beams are collinear and they exhibit a weak divergence. On Figure 3 are plotted the twin photons flux measured as a function of the pump intensity for the three runs: CW, ns and ps. Two regions are distinguishable from either side of an intensity I lim p
40 MW cm �2 the first one, for I p below I lim p, corresponds to a linear increase of the twin-photon flux; the second one, above I lim p
, relates to an exponential increase.
Note that I lim p also corresponds to the intersection of the NMM / NHM curve and the SCM curve.
The error bars for the pump intensity shown in Figure 3 are very large when using the 10 Hz-repetition rate picosecond pump laser because of strong spatial beam instabilities leading to large fluctuations of the beam radius. The shot by shot twin photon flux uncertainty is very big due to these pump intensity fluctuations, but an averaging allowed us to reduce the corresponding vertical error bars. Note that we kept the shot by shot horizontal uncertainty on the plot, because as discussed in [ 12 ], an averaging with pump intensity fluctuations in this highly nonlinear regime leads to a small overestimation of the twin photon flux.
3.2 Theory
Equation( 7) is plotted in Figure 3: As for the experimental data, the theoretical curve exhibits a linear part and an
Fig. 3. Measured and calculated SPDC photon flux generated in a 1-cm long x-cut KTP crystal as a function of the incident pump intensity. I lim p is the pump intensity delimiting the low and high pump intensity regimes of SPDC. SCM stands for semiclassical model( present work), NMM for nonlinear momentum model [ 10, 11 ] and NHM for nonlinear Hamiltonian model [ 12 ]. The interpolation plots for NMM and NHM models are obtained by multiplying the second-order nonlinearity v ð2Þ by a factor of 3, while the SCM it is obtained by multiplying the vacuum fluctuations amplitude E vacuum s; i by a factor of 2.3.
exponential part from either side of I lim p ð0Þ. This behavior can be explained by the existence of two different regimes of SPDC according to the relative value of E s; i and
E vacuum s; i
: One below a limit pump intensity I lim p ð0Þ, defining the low pump intensity regime, for which E s; i <
E vacuum s; i
, and the other one above I lim p ð0Þ, i. e., the high pump intensity regime, that corresponds to E s; i >
E vacuum s; i
. From equation( 7), it is possible to obtain an analytical expression describing these two regimes. For that, xsns x i n i
1 and E vacuum s E vacuum i are assumed,