J. Eur. Opt. Society-Rapid Publ. 21, 48( 2025) 177
It is important to notice that the fitting parameters have not the same mathematical impact regarding the different equations, which explains that the three interpolations can lead to the same curve. In the case of our model( SCM), the“ Interpolation” consists in a global multiplicative constant in front of the quantities DE vacuum s DE vacuum i in equation( 7). As a consequence, the fit does not affect the shape of the curve, which is not the case for the two quantum models( NMM and NHM) where the fitting parameter, at the level of v ðÞ 2 eff
( cf. Appendix B and C) acts outside and inside exponential functions.
Note that small pump intensity ranges were not investigated using the picosecond pump laser with several attenuators. The small level of twin flux N twin reported in Table 2 ranging between 10 4 and 10 7, it then would correspond to an average twin photon number of N pulse twin ¼ N twin ranging
10
from 10 3 and 10 6 twins generated per pulse using the 10 Hz picosecond source. But in this case, we were disturbed by a background noise coming from the pump laser synchronized with our measurements that we were unable to avoid despite notch filters.
5 Conclusion
We performed a second-order spontaneous parametric down-conversion experiment in a Type II phase-matched KTP crystal pumped at 532 nm and 527 nm along the x-axis of the crystal. Three pump sources have been used: In the CW, nanosecond and picosecond regimes. That allowed us to cover a pump intensity range from 2.4 W cm �2 to 3.7 GW cm �2 leading to the generation of twin photons with a flux N twin from 1.1 10 4 Hz to 1.2 10 21 Hz, respectively, the corresponding quantum efficiencies N twin / N p being 1.8 10 �11 and 9.2 10 �4. We identified two SPDC regimes regarding the pump intensity: One below 40 MW cm �2 for which the flux increases linearly, and the other one above 40 MW. cm �2 for which it behaves exponentially.
We proposed a semi-classical model under the undepleted pump approximation based on the quantum fluctuations of vacuum for the seeding of the process and a propagation ensured by single spatial mode classical fields, which allowed a satisfying description of these two regimes, with a much better agreement at high intensity than the quantum models based on the nonlinear momentum or the nonlinear Hamiltonian operators [ 11, 12 ]: The difference with respect to experiment reaches seven orders of magnitude with the quantum models, whereas it is one order of magnitude with our model. Then our model can be particularly useful for the design of high brightness twin-photon devices in the framework of space quantum telecommunications [ 22 ]. The other advantage of the semi-classical model over the quantum models is its simplicity of implementation and its possible numerical resolution.
However, the semi-classical and quantum approaches are complementary since the quantum models give access to a differentiation of these two regimes from the quantum point of view, i. e., a superposition of the vacuum state and the single biphoton Fock state at low pump intensity while multi-biphoton Fock states are involved at high pump intensity [ 12 ].
An additional validation of the semi-classical multimode modelling described in reference [ 9 ] would be brought by a comparison with the data produced in this article. The following of this work will be first to further improve of our semi-classical model in the high-gain regime, i. e., over the exponential part of the curves of Figure 3, by taking into account the broadening of the spectral bandwidth and the correlations between different modes [ 13 ]. In a second step, it will deal with quantum measurements in the two identified regimes, i. e., at low and high pump intensities, as well as the use of our semi-classical model for the twin-photon generation by four-wave-mixing, and also for triple-photon generation [ 23 – 24 ]. It would also be interesting to use our model for the description of optical parametric oscillation( OPO), in particular for the calculation of the oscillation threshold intensity. An additional perspective for this semi-classical modelling is the description of more complex experimental situations, such as simultaneously phase-matched cascaded second-order processes [ 25 ], allowed by the possible numerical integration of the equations.
Finally, from the technological point of view, it would be interesting to use OPOs, in particular Backward-wave OPOs, in order to get high intensity SPDC [ 26 ]. A comparison with other high gain regime experiments can also be performed [ 27 – 28 ].
Acknowledgments
The authors wish to thank David Jegouso and Corinne Félix for their technical support concerning the laser sources. Funding
This work was funded in part by the Program QuanTEdu-France n ° ANR-22-CMAS-0001 France 2030. Conflicts of interest The authors have nothing to disclose. Data availability statement Data are available upon reasonable request at the indicated e-mail. Author contribution statement
J. B. Software, Investigation, Writing – original draft. V. B. Investigation, Validation, Writing – original draft. B. B. Conceptualization, Methodology, Writing – original draft – review & editing.
References
1 Suhara T, Generation of quantum-entangled twin photons by waveguide nonlinear-optic devices, Laser Photonics Rev. 3( 4), 370 – 393( 2009). https:// doi. org / 10.1002 / lpor. 200810054 2 Walls DF, Squeezed states of light, Nature 306, 141 – 146
( 1983). https:// doi. org / 10.1038 / 306141a0. 3 Aspect A, Dalibard J, Roger G, Experimental test of Bell’ s inequalities using time-varying analyzers, Phys. Rev. Lett. 49( 25), 1804( 1982). https:// doi. org / 10.1103 / PhysRevLett. 49.1804.