Fire Code of the Philippines Ebook - SafetySignsPH.com Fire Code of the Philippines eBook - SafetySignsPH | Page 262

4. Matches shall not be stored within three meters (3 m) of any elevator shaft opening, open stairway, or other vertical opening; 5. Where shipping container that contain matches are opened, the contents shall be transferred in bins provided with metal-lined covers. 6. Where matches are sold in retail, original sealed packages shall be stored in shelves. When such packages are broken, individual boxes shall be stored in metal or metal-lined bins. B. On Fire Protection 1. Smoking is prohibited in areas where matches are stored. A “NO SMOKING” sign shall be conspicuously posted in designated areas. 2. The owner shall be responsible for the prompt removal of any hazardous condition, accumulations of combustible materials, including proper maintenance of equipment and safety devices. 3. Approved, supervised sprinkler system and portable fire extinguishers shall be provided throughout storage and manufacturing areas. C. Fire Safety Clearance A Fire Safety Clearance from City/Municipal Fire Marshal having jurisdiction shall be obtained for the storage and transportation of matches exceeding in aggregate twenty (20) matchman's gross (14,000 matches’ per matchman’s gross). SECTION 10.3.4.1.5 MAGNESIUM Magnesium shall be stored, handled and protected as follows: A. On Storage 1. Magnesium ingots, pigs, and billets shall be carefully piled on firm and generally level areas. Any combustible material shall not be stored within a distance of seven hundred sixty centimeters (760 cm) from any pile of magnesium pigs, ingots, and billets; 2. Outdoor storage of magnesium pigs, ingots and billets shall be in piles not exceeding forty five thousand four hundred kilograms (45,400 kg) each, separated by aisles with width not less than one-half (1/2) the height of the pile; 3. Storage of pigs, ingots and billets in buildings shall be on floors of non- combustible construction. Floors shall be well drained from water. Each pile shall not be larger than twenty three thousand kilograms (23,000 kg), and shall be separated by aisles with width not less than one-half 246