Field Installation and Service Manual IMS112 | Page 3
Step 2
Electrical Service
Access for Electrical Service at Back of Cabinet
1”
1-1/4”
Dia
1”
Drawer Guide
Back
Attatch
Stretcher
Cabinet
Back
112
2.2
Center the holes 1” down from the top of the
cabinet and in from the back attach stretcher.
2.1 When running access for electrical wiring that will
travel through more than one cabinet, drill 1-1/4” holes in
the upper back corner of the cabinet sides.
Step 3
This will allow the conduit to be run without interfering
with the top drawer or usable cabinet space.
Electrical Boxes (Typical Exterior Island End)
Access for Electrical Service at Back of Cabinet (Exterior View)
3.1 Locate the opening for the receptacle box so it does not inter-
fere with a top drawer.
Index the box to begin 2” from the back of a cabinet and 7” down from
the top of the box.
7”
Drawer Space
2”
Single Outlet
Cuttout
2-1/4” x 3-1/2”
Cabinet
Back
©2017 PCS Professional Cabinet Solutions. All Rights Reserved.