York HVAC Catalogue 2018 EN 2019 EN | Page 138

Compatibility table / Codes Model with AC motor (without air diffuser) Cassette YHKY Cassette YHKY-MP (IR remote control and sensor NOT included) Cassette YHKY-E - with electric resistance Cassette YHKY-MP-E - with electric resistance Cassette YHKY-REB with remote electric board 2 pipe system 4 pipe system 2 pipe system 4 pipe system 2 pipe system 2 pipe system 2 pipe system 4 pipe system YHKY 20 YHKY 25 YHKY 40 YHKY 50 YHKY 65 YHKY 95 YHKY 110 - - 0079100K 0079110K 0079170K 0079180K - - 0079120K 0079130K 0079000K 0079010K 0079171K 0079181K 0079060K 0079191K 0079020K 0079030K 0079002K 0079012K 0079173K 0079183K 0079062K 0079193K 0079022K 0079032K 0079003K 0079013K 0079174K 0079184K 0079063K 0079194K 0079023K 0079033K 0079004K 0079014K 0079175K 0079185K 0079064K 0079195K 0079024K 0079034K 0079005K 0079015K 0079176K 0079186K 0079065K 0079196K 0079025K 0079035K - - - - - - - - - - - - - - - - - YHKY 25 YHKY 40 YHKY 50 YHKY 65 YHKY 95 - YHKY 125 YHKY 150 - - - - - - 0079801K 0079811K 0079911K 0079921K 0079841K 0079901K 0079804K 0079814K 0079914K 0079924K 0079844K 0079904K 0079805K 0079815K 0079915K 0079925K 0079845K 0079905K - - - - - - 0079807K 0079817K 0079917K (6) 0079927K (6) 0079847K 0079907K Model with ECM motor (without air diffuser) Cassette YHKY-ECM - basic model Cassette YHKY-MP- ECM (IR remote control and sensor NOT included) Cassette YHKY-ECM-E - with electric resistance Cassette YHKY-ECM-MP-E - with electric resistance 2 pipe system 4 pipe system 2 pipe system 4 pipe system 2 pipe system 2 pipe system 0079001K 0079011K 0079172K 0079182K 0079061K 0079192K 0079021K 0079031K 0079802K 0079812K 0079912K 0079922K 0079842K 0079902K 0079803K 0079813K 0079913K 0079923K 0079843K 0079903K 0079808K 0079818K 0079918K (6) 0079928K (6) 0079848K 0079908K Mandatory accessories (units cannot work without them) Air diffuser - intake grid, frame and louvres in RAL 9003 white colour AKPA 600 AKPA 800 AKPA 900 Accessories (factory fitted) Valves (220V On/Off) 3 way valve + mounting kit for 2 pipe models (factory fitted) 3 way valve + mounting kit for 4 pipe models (factory fitted) 2 way valve + mounting kit for 2 pipe models (factory fitted) 2 way valve + mounting kit for 4 pipe models (factory fitted) 2 way DN 15 balance valve for main coil + connection kit (fact. fitted) * 2 way DN 20 balance valve for main coil + connection kit (fact. fitted) * 2 way DN 15 balance valve for additional coil + connection kit (fact. fitted) * 9079510 9079512 9079515 9079517 9079771 9079511 9079513 9079516 9079518 9079923 9079933 9079921 9079931 - - - 9079791 - 9079773 - 9079792 9079793 Accessories (supplied loose) Air diffusers / Panels Air diffuser - other colours (*) Contact Johnson Controls Valves (220V On/Off) 3 way valve + mounting kit for 2 pipe models (not fitted) 3 way valve + mounting kit for 4 pipe models (not fitted) 2 way valve + mounting kit for 2 pipe models (not fitted) 2 way valve + mounting kit for 4 pipe models (not fitted) 2 way DN 15 balance valve for main coil + connection kit (not fitted) * 2 way DN 20 balance valve for main coil + connection kit (not fitted) * 2 way DN 15 balance valve for additional coil + connection kit (not fitted) * Other type of valves 9079500 9079502 9079505 9079507 9079761 9079501 9079503 9079506 9079508 9079781 - 9079763 - 9079782 9079783 Contact Johnson Controls 9079922 9079932 9079920 9079930 - - - Other Accessories Outer casing OCA 600 Outer casing OCA 800 3 way valve + mounting kit for units with outer casing OCA (not fitted) Fresh air duct FAD Fresh air kit 1 way not suitable for units with outer casing OCA - FAK 600 Fresh air kit 1 way not suitable for units with outer casing OCA - FAK 800 Fresh air kit 1 way not suitable for units with outer casing OCA - FAK 900 MD-600 Metal Grid MD-800 Metal Grid 9079240 - - 9079250 9079221 9079155 6078005 9079230 - - - 9079231 - - 9079420 - - 9079417 CONTROLS for YHKY (AC versions) Remote three speed control JWC-3V (1) (4) Remote three speed control + electronic thermostat and manual S/W switch JWC-T (2) Remote three speed control + electronic thermostat and centralized/ manual S/W switch JWC-TQR (2) (3) Automatic speed control with electronic thermostat and S/W switch - JWC-AU (to be used with JPF-AU and JP-AU only) (2) (3) Automatic speed control with electronic thermostat to be mounted in the light wall box WM-503 (to be used with UP-503 only) Electromechanical thermostat T2T (4) (5) Power unit JPF-AU for JWC-AU and JTM-B remote controls, fitted on the unit Power unit JP-AU for JWC-AU and JTM-B remote controls, not fitted on the unit Power unit UP-503 for WM-503 remote control only, not fitted on the unit 9066642 9066630K 9066632K 9066331E 9066676 9060174 9066641 9066640 9066677 Control accessories for all versions (supplied with separate packaging) Low temperature cut-out for control JWC-T Low temperature cut-out for controls JWC-TQR, WM-503 and JP-AU power unit T2 sensor to be used as Change-over for JP-AU power unit Change-over 15-25 for control JWC-TQR Receiver SEL2M 9053048 3021090 9025310 9053049 9079109 * For 4 pipes unit must consider both the valve for main coil than the valve for additional coil. (1) Not to be used with valves. (2) Can be used with valves and/or low temperature cut-out. (3) Can be used with Change Over. (4) Not suitable with -E electric heater. (5) Not to be used with low temperature cut-out. (6) Receiver included. 138 - - - - - - 9079235 - -