York HVAC Catalogue 2018 EN 2019 EN | Page 137

YORK ® AIR-CONDITIONING PRODUCTS YHK-ECM Inverter Hydro Cassette 1.8 to 15.1 kW Technical features Model -2 pipes Total cooling capacity 2 Pipes [kW] (1) Sensible cooling capacity 2 Pipes [kW] (1) Water flow in cooling 2 Pipes [l/h] (1) Pressure drop in cooling 2 Pipes [kPa] (1) Heating capacity 2 pipes [kW] (2) Pressure drop in heating 2 pipes [kPa] (2) max 10v med 5v min 1v max med min max med min max med min max med min max med min YHK-ECM 25-2 2.73 2.16 1.84 2.07 1.60 1.35 473 373 317 10.1 6.6 4.9 2.87 2.22 1.85 9.4 5.9 4.3 YHK-ECM 40-2 4.30 3.04 2.24 3.15 2.16 1.57 744 524 385 15.1 9.4 4.6 4.36 2.98 2.12 13.2 6.6 3.6 YHK-ECM 50-2 4.96 3.85 2.55 3.68 2.79 1.80 864 666 441 19.7 12.4 5.9 5.15 3.85 2.46 17.8 10.6 4.7 YHK-ECM 65-2 6.30 5.13 4.20 4.69 3.75 3.02 1 089 885 723 22.7 15.6 10.9 6.70 5.30 4.27 21.6 14.2 9.6 YHK-ECM 95-2 YHK-ECM 125-2 YHK-ECM 150-2 10.69 12.60 15.13 7.69 9.43 11.38 5.28 6.36 7.86 7.83 9.31 11.41 5.50 6.77 8.30 3.68 4.45 5.58 1 848 2167 2602 1 328 1622 1957 909 1094 1352 33.0 22.7 31.8 18.5 13.4 18.8 9.4 6.6 9.6 10.56 13.39 16.40 7.34 9.59 11.86 4.90 6.18 7.82 28.1 21.5 31.0 14.6 11.8 17.3 7.0 5.4 8.2 max med min max med min max med min max med min max med min max med min max med min max med min max med min max med min YHK-ECM 25-4 2.75 2.17 1.85 2.06 1.59 1.34 476 375 318 9.5 6.2 4.6 3.18 2.51 2.13 311 245 209 9.4 6.1 4.6 535 380 310 47 39 33 38 30 24 YHK-ECM 40-6 3.90 2.81 2.09 2.92 2.03 1.49 676 483 359 10.3 5.6 3.3 2.91 2.20 1.73 288 217 170 6.7 4.1 2.6 710 445 310 54 43 33 45 34 24 YHK-ECM 50-6 4.47 3.51 2.37 3.40 2.60 1.70 779 608 409 13.1 8.4 4.1 3.29 2.66 1.92 326 263 189 8.4 5.7 3.2 880 610 360 60 50 37 51 41 28 YHK-ECM 95-6 YHK-ECM 125-4 YHK-ECM 150-4 9.76 11.61 13.59 7.14 8.86 10.59 4.97 6.07 7.45 7.29 8.87 10.68 5.17 6.53 7.96 3.51 4.33 5.4 1 697 1997 2337 1 233 1524 1821 856 1044 1281 30.1 22.6 30.4 17.0 13.8 19.1 8.8 7.0 10.1 8.33 10.55 12.17 6.27 8.4 9.8 4.58 6.01 7.19 818 907 1047 616 722 843 449 517 618 14.3 19.9 25.7 8.6 13.2 17.4 4.9 7.2 10.0 1 770 1 905 2480 1 130 1 290 1 650 710 790 1 025 57 58 64 47 49 55 34 38 44 48 49 55 38 40 46 25 29 35 28.5 1.4 0.25 275 575 575 44.0 2.1 0.40 275 575 575 81.0 2.1 0.70 275 575 575 YHK-ECM 65-4 6.48 5.29 4.29 4.80 3.82 3.07 1 120 908 740 19.8 13.6 9.4 8.24 6.65 5.41 805 649 528 18.1 12.3 8.5 1 165 870 630 48 39 33 39 30 24 230 /1 /50 43.5 3.0 0.40 303 820 820 Model -4 pipes Total cooling capacity 4 Pipes [kW] (1) Sensible cooling capacity 4 Pipes [kW] (1) Water flow in cooling 4 pipes [l/h] (1) Pressure drop in cooling 4 pipes [kPa] (1) Heating capacity 4 pipes [kW] (3) Water flow in heating 4 pipes [l/h] (3) Pressure drop in heating 4 pipes [kPa] (3) Air flow [m3/h] Sound power level [dB(A)] Sound pressure level [dB(A)] Power supply [V-ph-Hz] Power input [W] Water content (2 pipes) [l] Absorbed current [A] Dimensions (4) max Height Width Depth max mm mm mm 126.0 4.0 1.10 303 820 820 105.0 4.6 0.80 304 869 869 195.0 4.6 1.30 304 869 869 (1) Room temperature 27°C d.b., 19°C w.b. - Water temperature 7/12 °C (2) Room temperature 20°C - Water temperature: 45/40 °C (3) Room temperature 20°C - Water inlet temperature: 65/55°C (4) The sound pressure levels are 9 dB(A) lower than the sound power levels and apply to the reverberant field of a 100 m 3 room and a reverberation time of 0.5 sec. * Water flow values as Cooling, accordingly to the EUROVENT standards and UNI ENV 1397 Condensate pump integrated in all sizes Metal parts insulated to avoid condensation 2 or 3 way valves fitted or supplied loose in all sizes Manufacturer reserves the rights to change specifications without prior notice. 137 Outer casing as an option to integrate the water cassette into any enviroment