York HVAC Catalogue 2018 EN 2019 EN | Page 91

YORK ® AIR-CONDITIONING PRODUCTS Product Information Manufacturers are to provide to installers and end users instruction and access to a website that makes available (for free) a new “Technical Data Sheet” document summarizing the values used for the MEPS (Ƞs,c , SEPR or Ƞs,h) calculation. Below is an example of the “Technical Data Sheet” as it appears in regulation 2016/2281: Information requirements for comfort chillers Model(s): Information to identify the model(s) to which the information relates. General Information: Unit name, Air/Water cooled, type compressor Outdoor side heat exchanger of chiller: (select which: air or water/brine) Indoor side heat exchanger chiller: (default: water) Type: compressor driven vapour compression or sorption process If applicable: driver of compressor: (electric motor or fuel driven, gaseous or liquid fuel, internal or external combustion engine) Item Rated cooling capacity Symbol P rated,c Value x,x Unit Item Symbol Value Unit kW Seasonal space cooling energy efficiency Ƞ s,c x,x % Declared cooling capacity for part load at given outdoor temperature T i T j = + 35°C T j = + 30°C T j = + 25°C T j = + 20°C Degradation coefficient for chillers (*) Pdc Pdc Pdc x,x Declared energy efficiency ratio or gas utilisation efficiency/auxiliary energy factor for part load at given outdoor temperature T i kW x,x kW x,x kW Pdc x,x kW C dc x,x - T j = + 35°C EER d or GUE c,bin /AEF c,bin x,x % T j = + 30°C EER d or GUE c,bin /AEF c,bin x,x % T j = + 25°C EER d or GUE c,bin /AEF c,bin x,x % T j = + 20°C EER d or GUE c,bin /AEF c,bin x,x % Power consumption in modes other than "active mode" Off mode P OFF x,xxx kW Crankcase heater mode P CK x,xxx kW Thermostat off mode P TO x,xxx kW Standby mode P SB x,xxx kW For air-to-water comfort chillers: air flow rate, outdoor measured - x m 3 /h For air-to-water comfort chillers: air flow rate, outdoor measured - x m 3 /h Mode “On” information: Capacity, efficiency at different temperatures for partial load points A,B,C and D Mode “Off” information: Power input Auxiliaries (crankcase heater, stand-by mode, etc) Other items Capacity control Sound power level, outdoor Emissions of nitrogen oxides (if applicable) GWP of the refrigerant fixed / staged / variable L WA NO x (**) x,x/x,x x dB mg/kWh input GCV kg CO 2 eq (100 years) Standard rating conditions used: (low temperature application/medium temperature application) Contact details Other information: Sound, GWP, flow rates, application: • Floor heating/fancoils • Fancoils/Chilled beams Name and address of the manufacturer or of its authorised representative (*) If C dc is not determined by measurement then the default degradation coefficient of chillers shall be 0.9. (**) From 26 September 2018 Compliance All YORK products on the EU market comply with applicable Ecodesign regulations. In many cases YORK products offer significantly better energy efficiency than required by regulation, resulting in an attractively low cost of operation and lighter environmental footprint. 91