York HVAC Catalogue 2018 EN 2019 EN | Page 90

ENER Lot 21 - Central Heating and Cooling products (Comfort Chillers, High Temperature Process Chillers) Regulation 2016/2281 affects High Temperature Process Chillers and Comfort Cooling Chillers with rated cooling capacity below 2.000 kW. For Comfort Cooling Chillers, compliance is based on either Fan Coil application or Cooling Floor application. The manufacturer’s technical datasheet is to specify application(s) in compliance. A new KPI Ecodesign regulation introduces new Minimum Energy Performance Standards for Comfort Cooling Chillers (SEER), and Process Cooling Chillers (SEPR). In the case of SEPR it will be calculated in a similar way as for process chillers brine. In the case of (η s,c ), it will be calculated in a similar way to η s,h , used for comfort heating applications. ƞ s,c (%) =1/CC x SEER -∑ F i SEER – Seasonal Energy Efficiency Ratio CC – Conversion Coefficient Ratio between the annual cooling demand and the annual electrical input energy over the entire cooling season. SEER is calculated using standard EN14825, which takes the following into account: • S  easonal efficiency while the compressor is running (SEERon) • E  lectrical consumption when the compressor is not running: crankcase heater, standby or OFF mode European average coefficient that represents the amount of primary energy required to obtain electricity. CC is defined by the regulation with a constant value of 2,5. A better Indicator Similar to current ESEER η s,c and SEER and SEPR are better performance indicators for cooling, as they take into account temperature bins and hours based on weather data from cities throughout central Europe. Seasonal Energy Efficiency Ratio (SEER) is calculated similar to Eurovent Seasonal Energy Efficiency Ratio (ESEER). SEER however uses a different set of ambient temperatures and different weighting as a reference. As a result, SEER values are ALWAYS less than ESEER values. As displayed on the chart below, Process Chillers (SEPR) account for a wider range of temperatures than Comfort Chillers (SEER), which only consider temperatures down to 15°C. ∑ F i – Correction Factors Water-cooled chillers ∑ F i = 8% 120 450 100 400 350 ∑ F i = 3% Air-cooled chillers 300 250 200 150 100 D 80 B 60 40 C Eurovent Comfort Ecodesign Process Ecodesign A/C Comfort D 20 50 0 -20 -15 -10 -5 0 5 10 15 20 25 30 0 -20 -15 -10 -5 35 Ambient temperature [°C] Bin hours Process Chillers (SEPR) A B C 0 5 10 15 20 Ambient temperature [°C] 25 30 35 40 Bin hours Comfort Chiller (SEER) Eco-Design Requirements for Process Chillers High Temperature MEPS - Minimum Efficiency Performance Standards = SEPR Heat transfer medium at the condensing side Air Water Minimum SEPR value Minimum SEPR value Minimum η s,c value Minimum η s,c value Rated refrigeration capacity TIER 1 (Jan'18) TIER 2 (Jan'21) TIER 1 (Jan'18) TIER 2 (Jan'21) P A < 400 kW P A ≥ 400 kW P A < 400 kW 400 kW ≤ P A < 1 500 kW P A ≥ 1 500 kW 4.5 5.0 6.5 7.5 8.0 5.0 5.5 7.0 8.0 8.5 149 161 196 227 245 161 179 200 252 272 90