PHC-100A
PHC-100A
Interface Converter
Network
Terminal
• This product requres the knowledge to program with ASCII
commands to output through an RS-232C port.
DC Jack
RS-232C Port D-Sub 9P
Male Connector
Reset Switch
100
Connect-disconnect Lever
Wire Insertion
31
35
115
• 16 terminals provide 8 isolated non-voltage contact outputs.
• Reset pushbutton provided to reset all outputs to the off state.
Dimensions
117.5
The PHC-100A Interface Converter can be
connected to the RS-232C port on your
programmed PC to control most PATLITE
products, both visual and audible.
Terminal Block
(Unit: mm)
Specifications
PHC
Power
Input
Device
Power
Input
Model
data
RS232C
Signal wires
Command
Transfer data to turn on relay circuit 1
from PC.
Data
@??101!
Relay 1 is turned on.
Signal wires
Transfer data to turn on relay circuit 2
from PC.
Data
@??102!
@??106!
RS232C
Command
Relay 2 is turned on.
Turn on
circuit 2.
data
Signal wires
Transfer data to turn on relay circuits 2
and 3 from PC.
Data
Turn on
circuit 1
data
RS232C
Command
Relays 2 and 3 are turned on.
Turn on
circuit 2 and 3
PHC-100A
Interface
Method
Baud Rate
Communication Data Bit
Protocol
Stop Bit
Parity Bit
Flow Control
I/O Port
Contact Type
Contact Outputs
PHC Base
Output Load
Terminal Buss Capacity
Specifications Connector
Applicable Wire Size
RS-232C (Based on EIA)
Half-duplex, Full-duplex, Asynchronous
9,600 bps
8 bit
1 bit
None
None
D-sub 9 pin Male Connector
Non-voltage Contact
8
AC 125V 3A / DC 30V 3A
data
Signal wires
RS232C
PHE Base
Specifications
Screwless Terminal
Solid Wire: AWG18 - 26 (0.4 - 1.2mm2)
Stranded Wire: AWG20 - 22 (0.3 - 0.75mm2)
Dimensions (mm)
100(W) x 31(H) x 115(D)
Power Supply Source AC Adaptor (Sold Separately)
Power Consumption 4.0W
Operating
0oC to +40oC
Temperature Range
Humidity
20 to 80% RH (No Condensation)