PHE-3FBE1
PHE-3FBE1
RS-232C / PC Controlled Signal Tower
LED
• This product requres the knowledge to program with ASCII
commands to output through an RS-232C port.
φ40
+
35
-
12
Dimensions
DC 24V
Signal Tower can be controlled directly
by PC through RS-232C.
RS-232C
2 Alarm Sounds
85dB at 1m
Φ40
Network
FEATURES
Alarm is adjustable up to 85dB at 1m
High-volume alarms (two patterns) can be heard even in a noisy factory.
Bright LED signal tower
PATLITE’s original double reflection system with its exclusive hybrid prism-cut lens and
3 color LED modules create distinctive illumination that is bright and even.
• Light and alarm functions can be turned off by pressing the reset switch on the base.
(35)
31
228
259
•
•
•
•
100
115
(2.5)
(Unit: mm)
Specifications
Model
Interface
Method
Baud Rate
Communication Data Bit
Protocol
Stop Bit
Parity Bit
Flow Control
I/O Port
Signal Tower
Flashing Rate
Specifications Sound Level
Tone Pattern
PHE Base
Specifications
40
PHE-3FBE1
RS-232C (Based on EIA)
Half-duplex, Full-duplex, Asynchronous
9,600 bps
8 bit
1 bit
None
None
D-sub 9 pin Male Connector
60 flashes per minute
Adjustable from 70dB to 85dB (at 1m)
2 Alarms (Slow Intermittent, Fast
Intermittent)
Dimensions (mm)
100(W) x 259(H) x 115(D)
Power Supply Source AC Adaptor (Sold Separately)
Power Consumption 6.5W
Operating
0oC to +40oC
Temperature Range
Humidity
20 to 80% RH (No Condensation)
PHE-3FBE1 / PHC-100A Control
@ ? ? 1 27 !
Header
@ [40H]
1Byte
ID No.
2Byte
? ? [3FH] [3FH]
Please use the default value [??], which
allows this product to function without
specifying an ID No.
Output No.
1
2
3
4
5
6
7
8
Function1
Steady Red On
Steady Amber On
Steady Green On
Alarm 1 On
Alarm 2 On
Flashing Red On
Flashing Amber On
Flashing Green On
Communication Data / Settings
* Transmission Code : ASCII
* Return Codes : ACK [06H]
NACK [15H]
Output Action
0 [30H] … Output Off
1 [31H] … Output On
? [3FH] … Enter ID No
Output Select
Example
ASCII [Hex]
Bits (BCD)
Output No.
1Byte
2Bytes
Data1
Data2
2 [32H] 7 [37H]
00110010 00110111
8765
4321
The position of the '1' in the Binar y Coded
Decimal value specifies the Output No. acted
upon according to the Output Action Byte
specifed above.
End Code
! [21H]
The above example shows how to turn on the following output numbers : 6, 3, 2, 1
1Byte