Test Drive carrier katalog | Page 48

AIR-COOLED LIQUID CHILLERS WITH INTEGRATED HYDRONIC MODULE Air conditioning 30RBM/30RBP Options • Low leaving water temperature down to -6°C* • Very low leaving water temperature down to -12°C* • High static fan for ducted application* • Low noise level • Very low noise level • Grilles • Side panels • Electronic starter • Winter operation for OAT down to -10°C • Winter operation for OAT down to -20°C • High ambient • Evaporator frost protection • Evaporator and hydronic module frost protection • Partial heat reclaim* • Total Heat reclaim* • Master/slave operation • Suction and discharge valves • Hydronic module with high-pressure single or dual pump • Hydronic module with low-pressure single or dual pump • Hydronic module with greenspeed® single or dual pump • Expansion tank • Direct-expansion free-cooling (one or two circuits)* • Hydronic free-cooling* • J-Bus, BacNet or LonTalk gateways • Enviro-Shield, Super Enviro-Shield coatings for MCHE coils • Connection sleeve • 230V electrical plug • Touch Pilot operator interface • Power Factor correction* • Electric energy meter Features • Twelve sizes with nominal cooling capacities from 164 to 528 kW • Aquasnap liquid chillers for commercial and industrial applications. • 30RBM version with full load energy efficiency up to 3.1 (in accordance with EN14511-3: 2013) • 30RBP version with enhanced part-load energy efficiency using greenspeed® condenser fans. • 30RBP version with greenspeed® condenser fans for start-stop noise elimination. • Extra energy savings through multiple options*: greenspeed® variable speed pump, partial or total heat reclaim, partial or total free-cooling, electric energy meter. • All-aluminium micro-channel condenser (MCHE) and brazed plate heat exchanger for low R-410A refrigerant charge. • Night mode control. • V-shaped condenser coils allowing protection against hail. • Fast commissioning, as all units are systematically run tested before shipment. • Leak-tight refrigerant circuit and reduced maintenance costs. • Auto-adaptive control algorithm and automatic compressor unloading for increased and efficiency optimization. • Exceptional endurance tests for superior reliability. \\MAINMENU\STATUS CAPB_T DEM_LIM SP CTRL_PNT EMSTOP 0 100 4.2 -28.9 dsable % % °C °C Circuit B Total Capacity START/STOP * Options available after official product launch. Please contact your sales representative for more information. ENTER PRO-DIALOG+ Pro-Dialog+ operator interface 46 Touch Pilot operator interface