Eppendorf Liquid Handling Instruments
6
Automated liquid handling
epMotion ® 96 epMotion ® 5070 epMotion ® 5070f epMotion ® 5073 epMotion ® 5075
Pipetting of
aqueous liquids with
96 channels at once Serial pipetting of
aqueous, viscous
and volatile liquids in
automated way for easy
tasks on small foot print Serial pipetting of
aqueous, viscous and
volatile liquids in auto-
mated way in cell culture
bench or fume hood Serial pipetting of
aqueous, viscous and
volatile liquids in auto-
mated way for routine
tasks Serial pipetting of aqueous,
viscous and volatile liquids
in automated way with
highest flexibility and tool
options
Semi-automated
96 channel pipette
Electronic Automated
Liquid Handling
Automation Automated
Liquid Handling
Automation Automated
Liquid Handling
Automation Automated
Liquid Handling
Automation
Air-cushion Air-cushion Air-cushion Air-cushion Air-cushion
Intuitive and fast pipetting
in 96 and 384 format Reproducible,
contamination-free,
contactless pipetting at
high precision and
accuracy
0.2–1,000 µL,
1 & 8 channel
Automatic exchange
of 2 dispensing tools,
tablet or PC control Same as 5070 but
operation in laminar
flow bench or fume hood Same as 5070 but
more flexibility with
6 deck positions and
more features Same as 5070 but
full flexibility with
15 deck positions and
even more features
0.2–1,000 µL,
1 & 8 channel
Automatic exchange
of 2 dispensing tools,
tablet or PC control 0.2–1,000 µL,
1 & 8 channel
Same as 5073 plus 3 ther-
mal modules, Automatic
exchange of 4 dispensing
tools, Vacuum separation
No, but chip tool
identification and
calibration warning
Yes (tools) No, but chip tool
identification and
calibration warning
Yes (tools) epT.I.P.S. ®
Motion reload system epT.I.P.S. ®
Motion tips as racks
or reloads epT.I.P.S. ®
Motion tips as racks
or reloads 0.2–1,000 µL,
1 & 8 channel
Same as 5070 plus grip-
per transport, 1 thermal
module, ThermoMixer,
magnetic separation
HEPA filter & UV light
No, but chip tool
identification and
calibration warning
Yes (tools), UV light and
HEPA filter (optional)
epT.I.P.S. ®
Motion tips as racks
or reloads No, but chip tool
identification and
calibration warning
Yes (tools), UV light and
HEPA filter (optional)
epT.I.P.S. ®
Motion tips as racks
or reloads
> > Eppendorf Quality™
> > PCR clean
> > PCR clean & sterile > > Eppendorf Quality™
> > PCR clean
> > PCR clean & sterile > > Eppendorf Quality™
> > PCR clean
> > PCR clean & sterile > > Eppendorf Quality™
> > PCR clean
> > PCR clean & sterile > > Eppendorf Quality™
> > PCR clean
> > PCR clean & sterile
22 23 23 24 25
0.5–300 µL,
10–1,000 µL
2-position lifting table
No
No
Automated liquid handling
Easy programming of liquid handling steps for aspiration, dispensing or multi-dispensing of defined liquid classes,
temperature incubations, plate-mixing, vacuum, or magnetic bead separations.