Stainless steel manifold tubes for AI data center cooling

As server racks use more power, liquid cooling is becoming standard. This places greater demands on manifolds and leaves less room for failure. Stainless steel is a strong choice because it is approved for contact with coolant and has a proven track record in mass-produced laser-welded rectangular and square tube manifolds.
By Tommi Purtilo, M. Sc.( Tech), Business Development Manager, Stalatube Group
As AI and high-performance computing generate more heat than air cooling can handle, liquid cooling has moved from a niche solution to a baseline requirement. Analysts give different estimates, but most expect direct-tochip( D2C) cooling infrastructure to grow by more than 10 % per year in the coming years. This growth is driven by server racks becoming too powerful for traditional air cooling. One key component in every installation is often overlooked: the coolant distribution manifold. It can determine whether the entire system succeeds. A manifold sends coolant coming from the coolant distribution unit( CDU) to multiple server loops and back. It sounds simple, but the design is complex. It must hold pressure without leaking for a decade, resist corrosion, fit within a few centimetres of usable space behind a rack’ s cable management, and still let a technician blind-mate a server into place in seconds. If designed wrong, servers may overheat and lose performance. In the worst case, a coolant leak can cause downtime in a fully loaded rack.
A common qualification standard for the industry While requirements for liquid cooling manifolds may still vary, the Open Compute Project( OCP) has published“ Guidelines to Rack Manifold Requirements and Qualification.” Authored by Intel in collaboration with industry leaders such as CoolIT, Ingrasys / Foxconn, Wistron, Delta, Supermicro, CEJN, and SouthCo, this white paper provides clear guidelines for manufacturing high-quality, fully qualified manifolds suitable for both standard 19-inch EIA-310-D racks and Open Rack V3( ORV3) architectures. The following numbers involved show how demanding use the manifold is subjected to: The guideline calls for a minimum burst pressure of three times the maximum allowable working pressure( MAWP), hydrostatic pressure testing per ASME B31.3 at both 100 psig and 300 psig, and 5,000-cycle durability testing( 0 to 150 psig, three-second dwell) with full performance retained at cycle zero and cycle 5,000. Operating
www. stainless-steel-world. net Stainless Steel World October 2026 33