Service Center Solahart (081313462267) water heater | Page 33
33-1197 Solahart Owner‟s Manual – Thermosiphon Systems - Revision H – Nov 2013
Model
Demand
31
59.6°N
49.5°N
46.8°N
38.0°N
222KF
140 litres / day
Qd
QL
f-sol
MJ/a
MJ/a
%
7772
4314
55.5
7450
4545
61.0
8435
6832
81.0
5784
5310
91.8
222KF
200 litres / day
Qd
QL
f-sol
MJ/a
MJ/a
%
11103 5529
49.8
10643 5939
55.8
12050 8748
72.6
8263
7139
86.4
222KF
250 litres / day
Qd
QL
f-sol
MJ/a
MJ/a
%
13879 6218
44.8
13304 6798
51.1
15063 9806
65.1
10329 8366
81.0
222KF
300 litres / day
Qd
QL
f-sol
MJ/a
MJ/a
%
16655 6645
39.9
15965 7376
46.2
18075 10375 57.4
12395 9333
75.3
59.6°N
49.5°N
46.8°N
38.0°N
301KF
200 litres / day
Qd
QL
f-sol
MJ/a
MJ/a
%
11103 3930
35.4
10643 4427
41.6
12050 5958
49.7
8263
5735
69.4
301KF
250 litres / day
Qd
QL
f-sol
MJ/a
MJ/a
%
13879 4191
30.2
13304 4749
35.7
15063 6371
42.3
10329 6476
62.7
301KF
300 litres / day
Qd
QL
f-sol
MJ/a
MJ/a
%
16655 16655 26.2
15965 15965 31.0
18075 18075 36.6
12395 12395 56.1
301KF
400 litres / day
Qd
QL
f-sol
MJ/a
MJ/a
%
22206 22206 20.3
21286 21286 24.2
24100 24100 28.4
16526 16526 44.1
59.6°N
49.5°N
46.8°N
38.0°N
302KF
200 litres / day
Qd
QL
f-sol
MJ/a
MJ/a
%
11103 5540
49.9
10643 5949
55.9
12050 8688
72.1
8263
7114
86.1
302KF
250 litres / day
Qd
QL
f-sol
MJ/a
MJ/a
%
13879 6259
45.1
13304 6838
51.4
15063 9776
64.9
10329 8366
81.0
302KF
300 litres / day
Qd
QL
f-sol
MJ/a
MJ/a
%
16655 6762
40.6
15965 7503
47.0
18075 10465 57.9
12395 9383
75.7
302KF
400 litres / day
Qd
QL
f-sol
MJ/a
MJ/a
%
22206 7173
32.3
21286 8131
38.2
24100 10966 45.5
16526 10841 65.6
59.6°N
49.5°N
46.8°N
38.0°N
303KF
200 litres / day
Qd
QL
f-sol
MJ/a
MJ/a
%
11103 6207
55.9
10643 6535
61.4
12050 9833
81.6
8263
7610
92.1
303KF
250 litres / day
Qd
QL
f-sol
MJ/a
MJ/a
%
13879 7300
52.6
13304 7769
58.4
15063 11598 77.0
10329 9224
89.3
303KF
300 litres / day
Qd
QL
f-sol
MJ/a
MJ/a
%
16655 8211
49.3
15965 8828
55.3
18075 12996 71.9
12395 10647 85.9
303KF
400 litres / day
Qd
QL
f-sol
MJ/a
MJ/a
%
22206 9371
42.2
21286 10345 48.6
24100 14725 61.1
16526 12890 78.0
Stockholm
Wurzburg
Davos
Athens
59.6°N
49.5°N
46.8°N
38.0°N
443KF
250 litres / day
Qd
QL
f-sol
MJ/a
MJ/a
%
13879 7883
56.8
13304 7942
59.7
15063 11854 78.7
10329 9337
90.4
443KF
300 litres / day
Qd
QL
f-sol
MJ/a
MJ/a
%
16655 8960
53.8
15965 9084
56.9
18075 13412 74.2
12395 10845 87.5
443KF
400 litres / day
Qd
QL
f-sol
MJ/a
MJ/a
%
22206 10637 47.9
21286 10941 51.4
24100 15689 65.1
16526 13403 81.1
443KF
600 litres / day
Qd
QL
f-sol
MJ/a
MJ/a
%
33309 12091 36.3
31929 12804 40.1
36150 17497 48.4
24789 16857 68.8
Model
Demand
444KF
250 litres / day
Qd
QL
f-sol
MJ/a
MJ/a
%
59.6°N 13879 8036
57.9
49.5°N 13304 8408
63.2
46.8°N 15063 12668 84.1
38.0°N 10329 9647
93.4
444KF
300 litres / day
Qd
QL
f-sol
MJ/a
MJ/a
%
16655 9227
55.4
15965 9738
61.0
18075 14623 80.9
12395 11366 91.7
444KF
400 litres / day
Qd
QL
f-sol
MJ/a
MJ/a
%
22206 11236 50.6
21286 12048 56.6
24100 17810 73.9
16526 14427 87.3
444KF
600 litres / day
Qd
QL
f-sol
MJ/a
MJ/a
%
33309 13557 40.7
31929 15070 47.2
36150 21220 58.7
24789 18889 76.2
Location
Stockholm
Wurzburg
Davos
Athens
Model
Demand
Location
Stockholm
Wurzburg
Davos
Athens
Model
Demand
Location
Stockholm
Wurzburg
Davos
Athens
Model
Demand
Location
Stockholm
Wurzburg
Davos
Athens
Model
Demand
Location
Location
Stockholm
Wurzburg
Davos
Athens
Note: The over temperature protection tests have been carried out according to EN12976 with an irradiation higher than
20 MJ/m2/day. An over temperature protection device should be installed in the situation that irradiation this exposure
levels could be exceeded.