Service Center Solahart (081313462267) water heater | Page 33

33-1197 Solahart Owner‟s Manual – Thermosiphon Systems - Revision H – Nov 2013 Model Demand 31 59.6°N 49.5°N 46.8°N 38.0°N 222KF 140 litres / day Qd QL f-sol MJ/a MJ/a % 7772 4314 55.5 7450 4545 61.0 8435 6832 81.0 5784 5310 91.8 222KF 200 litres / day Qd QL f-sol MJ/a MJ/a % 11103 5529 49.8 10643 5939 55.8 12050 8748 72.6 8263 7139 86.4 222KF 250 litres / day Qd QL f-sol MJ/a MJ/a % 13879 6218 44.8 13304 6798 51.1 15063 9806 65.1 10329 8366 81.0 222KF 300 litres / day Qd QL f-sol MJ/a MJ/a % 16655 6645 39.9 15965 7376 46.2 18075 10375 57.4 12395 9333 75.3 59.6°N 49.5°N 46.8°N 38.0°N 301KF 200 litres / day Qd QL f-sol MJ/a MJ/a % 11103 3930 35.4 10643 4427 41.6 12050 5958 49.7 8263 5735 69.4 301KF 250 litres / day Qd QL f-sol MJ/a MJ/a % 13879 4191 30.2 13304 4749 35.7 15063 6371 42.3 10329 6476 62.7 301KF 300 litres / day Qd QL f-sol MJ/a MJ/a % 16655 16655 26.2 15965 15965 31.0 18075 18075 36.6 12395 12395 56.1 301KF 400 litres / day Qd QL f-sol MJ/a MJ/a % 22206 22206 20.3 21286 21286 24.2 24100 24100 28.4 16526 16526 44.1 59.6°N 49.5°N 46.8°N 38.0°N 302KF 200 litres / day Qd QL f-sol MJ/a MJ/a % 11103 5540 49.9 10643 5949 55.9 12050 8688 72.1 8263 7114 86.1 302KF 250 litres / day Qd QL f-sol MJ/a MJ/a % 13879 6259 45.1 13304 6838 51.4 15063 9776 64.9 10329 8366 81.0 302KF 300 litres / day Qd QL f-sol MJ/a MJ/a % 16655 6762 40.6 15965 7503 47.0 18075 10465 57.9 12395 9383 75.7 302KF 400 litres / day Qd QL f-sol MJ/a MJ/a % 22206 7173 32.3 21286 8131 38.2 24100 10966 45.5 16526 10841 65.6 59.6°N 49.5°N 46.8°N 38.0°N 303KF 200 litres / day Qd QL f-sol MJ/a MJ/a % 11103 6207 55.9 10643 6535 61.4 12050 9833 81.6 8263 7610 92.1 303KF 250 litres / day Qd QL f-sol MJ/a MJ/a % 13879 7300 52.6 13304 7769 58.4 15063 11598 77.0 10329 9224 89.3 303KF 300 litres / day Qd QL f-sol MJ/a MJ/a % 16655 8211 49.3 15965 8828 55.3 18075 12996 71.9 12395 10647 85.9 303KF 400 litres / day Qd QL f-sol MJ/a MJ/a % 22206 9371 42.2 21286 10345 48.6 24100 14725 61.1 16526 12890 78.0 Stockholm Wurzburg Davos Athens 59.6°N 49.5°N 46.8°N 38.0°N 443KF 250 litres / day Qd QL f-sol MJ/a MJ/a % 13879 7883 56.8 13304 7942 59.7 15063 11854 78.7 10329 9337 90.4 443KF 300 litres / day Qd QL f-sol MJ/a MJ/a % 16655 8960 53.8 15965 9084 56.9 18075 13412 74.2 12395 10845 87.5 443KF 400 litres / day Qd QL f-sol MJ/a MJ/a % 22206 10637 47.9 21286 10941 51.4 24100 15689 65.1 16526 13403 81.1 443KF 600 litres / day Qd QL f-sol MJ/a MJ/a % 33309 12091 36.3 31929 12804 40.1 36150 17497 48.4 24789 16857 68.8 Model Demand 444KF 250 litres / day Qd QL f-sol MJ/a MJ/a % 59.6°N 13879 8036 57.9 49.5°N 13304 8408 63.2 46.8°N 15063 12668 84.1 38.0°N 10329 9647 93.4 444KF 300 litres / day Qd QL f-sol MJ/a MJ/a % 16655 9227 55.4 15965 9738 61.0 18075 14623 80.9 12395 11366 91.7 444KF 400 litres / day Qd QL f-sol MJ/a MJ/a % 22206 11236 50.6 21286 12048 56.6 24100 17810 73.9 16526 14427 87.3 444KF 600 litres / day Qd QL f-sol MJ/a MJ/a % 33309 13557 40.7 31929 15070 47.2 36150 21220 58.7 24789 18889 76.2 Location Stockholm Wurzburg Davos Athens Model Demand Location Stockholm Wurzburg Davos Athens Model Demand Location Stockholm Wurzburg Davos Athens Model Demand Location Stockholm Wurzburg Davos Athens Model Demand Location Location Stockholm Wurzburg Davos Athens Note: The over temperature protection tests have been carried out according to EN12976 with an irradiation higher than 20 MJ/m2/day. An over temperature protection device should be installed in the situation that irradiation this exposure levels could be exceeded.