Service Center Solahart (081313462267) water heater | Page 32

30 33-1197 Solahart Owner ‟ s Manual – Thermosiphon Systems - Revision H – Nov 2013
ANNUAL PERFORMANCE CALCULATIONS FOR EUROPE
SYSTEM WIND AND SNOW LOAD PRESSURE
Under the requirements of EN 12795-1 ( European Standard ) the type of collector used in these systems has been tested ( ITW 11COL1015 ) to 2000 Pa , the maximum pressure ( positive and negative ) limit of the test equipment . This value has been used to determine the maximum permissible limits of wind load ( v m ) as 56.6 m / s ( 203.6 km / h ) and snow load ( s k ) as 2 kN / m 2 .
Systems or collector only installations using these collectors are only to be installed where the maximum values of s k ( snow load ) and v m ( mean wind velocity ) for the specific geographical area and installation circumstances do not exceed the European permissible limit of wind and snow load . Values of v m and s k for your area can be obtained by consulting the local dealer , a qualified structural engineer or relevant authorities .
These collectors and systems are routinely used in Australian Cyclonic regions .
KF SYSTEMS
Annual performance calculations of Solahart thermosiphon KF systems with the KF collector according to EN12976 SolarKeyMark Systems ITW Test Report 10SYS90-1 and 09SYS72 for the 151KF ( 150 tank , 1 collector ), 181KF ( 180 tank , 1 collector ), 182KF ( 180 tank , 2 collectors ), 221KF ( 220 tank , 1 collector ), 222KF ( 220 tank , 2 collectors ), 301KF ( 300 tank , 1 collector ), 302KF ( 300 tank , 2 collectors ), 303KF ( 300 tank , 3 collectors ), 443KF ( 440 tank , 3 collectors ) systems and 444KF ( 440 tank , 4 collectors ) systems .
Qd = energy demand QL = solar energy ( load ) f-sol = solar fraction
Model
151KF
151KF
151KF
151KF
Demand
80 litres / day
110 litres / day
140 litres / day
200 litres / day
Location
Qd
MJ / a
QL
MJ / a
f-sol
%
Qd
MJ / a
QL
MJ / a
f-sol
%
Qd
MJ / a
QL
MJ / a
f-sol
%
Qd
MJ / a
QL
MJ / a
f-sol
%
Stockholm
59.6 ° N
4441
2367
53.3
6107
2925
47.9
7772
3334
42.9
11103
3708
33.4
Wurzburg
49.5 ° N
4257
2512
59.0
5854
3167
54.1
7450
3658
49.1
10643
4193
39.4
Davos
46.8 ° N
4820
3726
77.3
6628
4606
69.5
8435
5204
61.7
12050
5712
47.4
Athens
38.0 ° N
3305
2961
89.6
4545
3831
84.3
5784
4546
78.6
8263
5553
67.2
Model
181KF
181KF
181KF
181KF
Demand
110 litres / day
140 litres / day
170 litres / day
200 litres / day
Location
Qd
MJ / a
QL
MJ / a
f-sol
%
Qd
MJ / a
QL
MJ / a
f-sol
%
Qd
MJ / a
QL
MJ / a
f-sol
%
Qd
MJ / a
QL
MJ / a
f-sol
%
Stockholm
59.6 ° N
6107
2852
46.7
7772
3233
41.6
9438
3492
37.0
11103
3631
32.7
Wurzburg
49.5 ° N
5854
3091
52.8
7450
3561
47.8
9047
3917
43.3
10643
4108
38.6
Davos
46.8 ° N
6628
4441
67.0
8435
4994
59.2
10243
5347
52.2
12050
5531
45.9
Athens
38.0 ° N
4545
3186
70.1
5784
3765
65.1
7024
4228
60.2
8263
4569
55.3
Model
182KF
182KF
182KF
182KF
Demand
80 litres / day
110 litres / day
140 litres / day
200 litres / day
Location
Qd
MJ / a
QL
MJ / a
f-sol
%
Qd
MJ / a
QL
MJ / a
f-sol
%
Qd
MJ / a
QL
MJ / a
f-sol
%
Qd
MJ / a
QL
MJ / a
f-sol
%
Stockholm
59.6 ° N
4441
2718
61.2
6107
3524
57.7
7772
4244
54.6
11103
5363
48.3
Wurzburg
49.5 ° N
4257
2823
66.3
5854
3688
63.0
7450
4478
60.1
10643
5790
54.4
Davos
46.8 ° N
4820
4227
87.7
6628
5560
83.9
8435
6740
79.9
12050
8507
70.6
Athens
38.0 ° N
3305
3143
95.1
4545
4240
93.3
5784
5269
91.1
8263
7015
84.9
Model
221KF
221KF
221KF
221KF
Demand
140 litres / day
200 litres / day
250 litres / day
300 litres / day
Location
Qd
MJ / a
QL
MJ / a
f-sol
%
Qd
MJ / a
QL
MJ / a
f-sol
%
Qd
MJ / a
QL
MJ / a
f-sol
%
Qd
MJ / a
QL
MJ / a
f-sol
%
Stockholm
59.6 ° N
7772
3381
43.5
11103
3886
35.0
13879
4080
29.4
16655
4180
25.1
Wurzburg
49.5 ° N
7450
3703
49.7
10643
4374
41.1
13304
4630
34.8
15965
4757
29.8
Davos
46.8 ° N
8435
5230
62.0
12050
5941
49.3
15063
6221
41.3
18075
6362
35.2
Athens
38.0 ° N
5784
4564
78.9
8263
5701
69.0
10329
6352
61.5
12395
6705
54.1