Service Center Solahart (081313462267) water heater | Page 28

33-1197 Solahart Owner‟s Manual – Thermosiphon Systems - Revision H – Nov 2013 26 OPEN CIRCUIT DIRECT SYSTEMS – THERMOSIPHON RESTRICTOR VALVE (TRV) A Thermosiphon Restrictor Valve (TRV) is available for use on an open circuit direct system to assist with over temperature protection of the system. The TRV locates in the top end of the cold pipe assembly. A non-standard cold pipe arrangement is required to accommodate the TRV. In Australia, a TRV must be used on a new installation of a 222, 303, 443 system regardless of the type of collector installed and on a 302 system installed with LCS collectors. When assembling the cold pipe, ensure: A Silicone Rubber Washer is used between the flared pipe ends and each end of the TRV. The TRV is to be orientated with the copper element probe facing upward toward the tank. The TRV has an arrow and the word „FLOW‟ stamped on the outside of the body. The arrow is to point upwards in the direction of the tank. If this pipe assembly is being retrospectively fitted to an existing system, replace existing O-Rings with the new ones to seal cold pipe to the tank/collector and extension pipe (if any). Cold Water Inlet Cold Pipe Assy TRV Upper 33-0171 (O-Ring) 34-4391 (TRV) The arrow stamped on the TRV body is to point toward the tank Cold Pipe Assy TRV Lower To Tank Inlet (Or Extension Pipe) 34-5096 (Silicone Rubber Washer) CAUTION! DO NOT OVERTIGHTEN FITTINGS. HANDTIGHTEN, THEN ADD HALF TURN ONLY WITH SPANNER, OTHERWISE DAMAGE TO WASHER MAY OCCUR. Thermosiphon Restrictor Valve (TRV) Assembly