BEFORE THE REFURB
equipment including their associated plinths, making way for a new and coveted storage space. project
Walking through the installation, Pengelly points out some of the more striking examples of legacy engineering. Dominating part of the plantroom is a backward‐curved, double‐inlet centrifugal, belt driven supply fan – one of two identical feats of past engineering. Each fan would have moved in the region of 30m ³/ s of air, giving a combined 60m ³/ s of supply air when both were running.
From there, the system unfolds into a classic large‐scale air‐handling layout comprising a labyrinth of masonry plantrooms. A dedicated and similar centrifugal return air fan feeds into a mixing chamber, where air streams are blended and then pushed on through a network of dampers, branch ducts and supply air plenums. These ducts pass through the wall that separates the plantroom from the trading floor, distributing conditioned air across the store.
Even the stores’ refrigeration system was woven into the comfort‐cooling strategy. Refrigeration pipework used to run through large underground trenches into the display cabinets, and the cold air‘ spillage’ from those cabinets was deliberately captured and ducted back to help with the cooling load. On top of that, an economy cycle provided free cooling: when the outdoor conditions were cool enough, the economy dampers would open, and outside air would be used to offset the need for mechanical cooling.
All of this – the chillers, fans, coils, ducts, pipework, fittings, pumps, dampers, louvers, air-tight doors, electrics, controls, walls, and plinths – is now marked for removal.
Chilled water pumps and pipework forming part of the legacy plant. Large coil sections mounted on steel frames will need to be cut out and craned or carried away in pieces. Existing ducts that currently feed into branch ducts serving the trading floor will be blanked off and rationalised, ensuring the new system has a clean slate to work from.
DEMOLITION, RECONFIGURATION AND REUSE Before the new equipment can go in, a significant amount of strip‐out and building work has to be done. The old plant areas are being emptied out completely. Heavy concrete plinths that once supported major items of plant are now in the way and must be removed.
RACA Journal I November 2026
The old electrical switchgear and control panels that once ran the plant, in a plantroom area already partly cleared ahead of the strip-out.