Résistance de l’ acier N sa( lb / ancrage) 13 110 |
ϕ acier = 0,75
ϕN sa lb / ancrage
9833
|
N ua, i( lb / ancrage)
1000
|
( N ua, i / ϕN sa)
10,2 %
|
OK |
Rupture du béton |
N cbg( lb)
29,194
|
ϕ béton = 0,65
ϕN cbg( lb)
18,976
|
N ua, g( lb) 8000 |
( N ua, g / ϕN cbg) 42,2 % |
OK COMMANDES |
force d’ adhérence |
N ag( lb)
36,807
|
ϕ adhérence = 0,65
ϕN ag( lb)
23,925
|
N ua, g( lb) 8000 |
( N ua, g / ϕN ag) 33,4 % |
OK |
tension soutenue |
0,55 ϕ adhérence N ba, soutenu( lb / ancrage)
6885
|
N ua, s( lb / ancrage) 750 |
( N ua, s / 0,55ϕN ba, s) 10,9 % |
OK |
|
Cisaillement |
|||||
ϕ acier = 0,65 |
|||||
Résistance de l’ acier |
V sa, eq( lb / ancrage)
7865
|
. V. S. A. V., eq( lb / ancrage) |
V ua, i( lb / ancrage) 625 |
( V ua, i / ϕV sa, eq) 12,2 % |
OK |
5112 |
|
Rupture du béton
( wrt x- bordure)( col 1)
Cas 1 / Cas2
|
( wrt x- bordure) V cbg, col 1( lb) 25,464 |
ϕ béton = 0,70( wrt x- bordure) Cas 1 / Cas2 ϕV cbg, col 1( lb) V ua, col 1 =( V ua, y)/ 2
17,825 = 2 500 lb
|
( V ua, col 1 / ϕV cbg, col 1) 14,0 % |
( wrt x- bordure) Cas 1 / Cas2 OK |
|
Rupture du béton
( wrt x- bordure)( col 2)
Cas 1 / Cas2
|
( wrt x- bordure) V cbg, col 2( lb) 60,394 |
ϕ béton = 0,70( wrt x- bordure) Cas 1 / Cas2 ϕV cbg, col 2( lb) V ua, col 2 = 1,0 V ua, y
42,276 = 5 000 lb
|
( V ua, col 2 / ϕV cbg, col 2) 11,8 % |
( wrt x- bordure) Cas 1 / Cas2 OK |
|
Rupture du béton
( wrt x + bordure)( col 2)
Cas 3
|
( wrt x + bordure) V cbg, col 2( lb) 48,016 |
ϕ béton = 0,70( wrt x + bordure) Cas 3 ϕV cbg, col 2( lb) V ua, col 2 = 1,0 V ua, y
33,611 = 5 000 lb
|
( V ua, col 2 / ϕV cbg, col 2) 14,9 % |
( wrt x + bordure) Cas 3 OK COMMANDES |
arrachement du béton |
V cpg( lb)
58,388
|
ϕ béton = 0,70
ϕV cpg( lb)
40,872
|
V ua,||, x( lb)
5000
|
( V ua,||, x / ϕV cpg)
12,2 %
|
OK |