Product Technical Guides : US-EN Firestop Systems Guide For Specifiers | Page 45

Product Information FIRESTOP BLOCK CFS-BL Product description • Ready-to-use, flexible intumescent firestop block designed for medium to large sized openings Product features No expiration date alleviates shelf life concerns Up to 12" annular space without requiring structural reinforcement “Grid Tech” technology for increased annular space Suitable for re-penetration or new penetrations Easy, one person installation and re-penetration No mess installation — no special tools required Ideal for use in floors — no forming required One sided systems available Halogen, asbestos and solvent free Operational immediately after installation Smoke resistant, non-curing, re-usable material • • • • • • • • • • • Areas of application NEW Grid-Tech! • Sealing single or multiple penetrations in small to large openings • Temporary or permanent sealing of cables and cable tray penetrations • Temporary or permanent sealing of insulated and non‑insulated metallic pipes and combustible pipe penetrations For use with Walls (UL tested up to max. opening 72" x 36") Floors (UL tested up to max. opening 72" x 36") Concrete, porous concrete, masonry and gypsum wall assemblies Wall assemblies rated up to 4 hours Floor assemblies rated up to 3 hours • • • • • Examples • Completely dust and fiber free rooms and places where electrical installations are frequently used (ie: computer centers, hospitals, laboratories, etc.) • New buildings in the construction phase and during renovation • Large openings containing multiple penetrations as found in production bays, warehouses, hospitals etc. • Areas of frequent re-penetration and planning for future capacity Installation instructions Technical Data Approx. 0.27 g/cm 3 Red Application temperature 40° F to 104° F (5° C to 40° C) Temperature resistance 5° F to 140° F (-15° C to 60° C) Intumescent activation Approx. 392° F (200° C) Expansion ratio (unrestricted) Up to 1:3 Surface burning characteristics (ASTM E 84-10b) Flame Spread Index: 10 Smoke Development Index: 15 Sound transmission classification (ASTM E 90) STC Rating: 52 (Relates to specific construction) Approvals California State Fire Marshal -No. 4485-1200:0143 Tested in accordance with UL 1479, ASTM E 814, ASTM E 84 FILL, VOID OR CAVITY MATERIALFOR USE IN THROUGH-PENETRATION FIRESTOP SYSTEMS SEE UL FIRE RESISTANCE DIRECTORY 66Y7 FM $33529(' Density Color • See Hilti Literature or third-party listings for complete application and installation details )RU3HQHWUDWLRQ)LUH6WRSV &RQVXOWWKH)DFWRU\0XWXDO5HVHDUFK&RUSRUDWLRQ$SSURYDO*XLGH Hilti Firestop Saving lives through innovation and education 43