Post-Installed Anchors in Masonry US English | Page 50

INSTALLATION INSTRUCTIONS
Installation Instructions For Use ( IFU ) are included with each product package . They can also be viewed or downloaded online at www . hilti . com ( US ), or www . hilti . ca ( Canada ). Because of the possibility of changes , always verify that downloaded IFU are current when used . Proper installation is critical to achieve full performance . Training is available on request . Contact Hilti Technical Services for applications and conditions not addressed in the IFU .
MATERIAL SPECIFICATIONS
Table 23 — Properties of fully-cured HIT-HY 270 adhesive
Compressive strength
ASTM D695 / DIN 53454
7,252-10,153 psi
50-70 MPa
Modulus of elasticity ( Compression test )
ASTM D790 / DIN 53452
246,568 psi
1,700 MPa
Water absorption
ASTM D570 / DIN 53495
3 - 8 %
Electrical resistance
VDE / DIN 0303T3
4.2 x 10 " ohm / in .
1.065 x 1012 ohm / cm
HILTI HIT-HY 270 CURE TIMES
[° F ] [° C ] t work t cure
23 – 32
-5 … 0
10 min
6 h
33 – 41
1 … 5
10 min
4 h
42 – 50
6 … 10
7 min
2.5 h
51 – 68
11 … 20
4 min
1.5 h
69 – 86
21 … 30
2 min
30 min
87 – 104
31 … 40
1 min
20 min
[° F ] [° C ] t work t cure
41
5
10 min
4 h
42 – 50
6 … 10
7 min
2.5 h
51 – 68
11 … 20
4 min
1.5 h
69 – 86
21 … 30
2 min
30 min
87 – 104
31 … 40
1 min
20 min
50 Masonry Fastening Technical Guide Edition 24 | 7.1 HIT-HY 270 HYBRID FOR MASONRY CONSTRUCTION Hilti , Inc . 1-800-879-8000 | en español 1-800-879-5000 | www . hilti . com | Hilti ( Canada ) Corporation | www . hilti . ca | 1-800-363-4458