Installation instructions
Installation Instructions For Use( IFU) are included with each product package. They can also be viewed or downloaded online at www. hilti. com( US), or www. hilti. ca( Canada). Because of the possibility of changes, always verify that downloaded IFU are current when used. Proper installation is critical to achieve full performance. Training is available on request. Contact Hilti Technical Services for applications and conditions not addressed in the IFU.
Material specifications
Table 28. Properties of fully cured HIT-HY 270 adhesive
Compressive strength ASTM D695 / DIN 53454 7,252-10,153 psi 50-70 MPa Modulus of elasticity( Compression test) ASTM D790 / DIN 53452 246,568 psi 1,700 MPa Water absorption ASTM D570 / DIN 53495 3- 8 % Electrical resistance VDE / DIN 0303T3 4.2 x 10 " ohm / in. 1.065 x 1012 ohm / cm
Hilti HIT-HY 270 cure times
Ordering information
50