The same process utilized for calculating tension breakout cones in face of CMU installations can be used for anchors in bed joint installations.
 5.0
 Design example— Fully grouted CMU construction
 The following design example, based on the masonry anchor design provisions of ICC-ES AC58, is intended for illustration purposes only.
 Parameters
 Tension failure modes
 Steel failure— Nominal strength
 N sa = A se, N f uta N sa = 0.1419 in. 2
 N sa = 8, 230 lbs
 58, 000 psi
 Masonry breakout failure— Nominal strength
 N mbg = A Nm A Nmo ψ ec, N, m ψ ed, N, m ψ c, N, m N b, m
 Anchor element
 • Hilti HIT-HY 200-R V3 Adhesive Anchor
 • HAS-V-36 Threaded Rod( ASTM F1554)
 • d anchor =. 500 inches | h ef = 5.00 inches
 Masonry parameters
 • Uncracked, Fully Grouted CMU Construction
 • Dry Masonry Conditions | Seismic Category A
 • Temperature Range A Conditions
 • f ́m = 1,500 psi | h = 8.00 inches( nominal)
 Design loads
 • N ua = 1,000 lbs
 • V ua, x = 1,000 lbs
 A Nm = 1.5h ef + 8 in. + 1.5h ef 5. 813 in. + 2. 187 in. A Nm = 7.5in. + 8in. + 7.5in.)( 8 in. A Nm = 184 in. 2
 A Nmo = 9 × h ef
 2
 A Nmo = 9 × 5 in. 2 A Nmo = 225 in. 2 ψ ec, N, m = 1.0( No Eccentricity Present)
 ψ ed, N, m = 0.7 + 0.3 c a, min 1.5h ef 2. 187 in. ψ ed, N, m = 0.7 + 0.3
 7.5 in. ψ ed, N, m = 0.787
 ψ c, N, m = 1.0( Found in ESR)
 10