POLYWARM® COATED CALORIFIERS WITH INTEGRATED HEAT PUMP
POLYWARM
STORAGE
Pmax
10 bar
®
Tmax
90 °C
1
BOLLY® - INTERKA
FINISHING
1
Electronic Central Unit (included):
- set point hot water
- self check
- anti-legionellosis treatement
- operating programs
- “BOOST” mode
2
External to the storage condensator
coil avoiding any contact coolant D.H.W.
De
Df
INT
2
1
Domestic cold water circuit inlet 1” Gas F
3
Connection for instrumentation 1/2” Gas F
4
Flange for inspection Ø 75 / Electrical
immersion resistance
5
Connection for instrumentation 1/2” Gas F
6
Anode 1"1/4 GAS F
7
Recirculation 1" GAS F
8
H6 (8)
Drain 1”1/4 Gas F
2
Domestic hot water outlet 1" GAS F
H5 (7)
H
H4 (5)(6)
ANODEN TESTER
Kontrolltaste drücken
Rot: Anoden wechseln
A
H3 (3)(4)
H2 (2)
H1 (1)
Water ignition time from 15 °C to 55 °C with C.O.P depending
on the external temperature
4,5
17:00
Ø180
16:00
15:00
4,0
(2) (7) (8)
14:00
13:00
3,5
Ignition time [h]
12:00
11:00
(3) (5)
(6)
C.O.P.
P.E.D. product planned and produced in conformity to the article 3.3 of directive 92/23/CE
P.E.D. product planned and produced in conformity to the article 3.3 of directive 92/23/CE
BOLLYTERM® HP
(4)
3,0
10:00
9:00
8:00
2,5
7:00
6:00
2,0
5:00
4:00
3:00
1,5
-5
0
7
15
Bollyterm® HP (200)
Bollyterm® HP (300)
C.O.P.
External temperature [°C]
Model
Net Volume
Df
De
Int
H
A
H1
[liters]
20
H2
H3
H4
H5
H6
[mm]
200
205
550
640
340
1585
1684
71
240
350
800
815
925
300
293
550
640
340
1960
2040
71
240
350
860
1190
1300
97