JEOS RP ISSN02 | Page 213

208
J. Eur. Opt. Society-Rapid Publ. 21, 52( 2025)
Figure 3. Results of simulations with sample height h = 2 mm and radius r = 50 mm.( a) Potential drop across plasma sheath,( b) and( c) current waveforms for the sample and the open part of the electrode respectively,( d) ion energy distribution( IED),( e) and( f) ion velocity and density waveforms. In( a),( d)–( f) the red-dashed line is for the open electrode path in EEC, and the blue line is for the sample path in EEC.
Figures 3e, 3f. The decreased ion velocity is compensated by increased ion density to maintain current continuity.
4.1 Sheath behavior without substrate
We begin by analyzing the simplest case of an electrode without a substrate. The RF voltage amplitude VRF was adjusted such that maximum sheath potential remained constant at V sub = 200 V for each simulated ICP power value. Maximum values for sheath potential, ion energies, and peak separation distance IEDs as functions of ICP power are presented in Figure 4a.
Despite the constant sheath potential, the maximum ion energy increases with rising ICP power, accompanied by a broadening of the IED. This behavior is consistent with previous findings [ 8 ] and can be attributed to the increase in plasma density, and consequently higher plasma ion frequency x ion ¼ðn o e 2 = ð 0 m ion ÞÞ 1 = 2. Ions respond stronger to the time-varying electric field, causing oscillations of the ion current( Fig. 4b). Broad and bimodal IED is the result at higher plasma ion frequency as can be seen in Figure 4c.
4.2 Effect of sample geometry
In this section, we show how sample geometry affects the plasma sheath. We start by considering the case when the sample diameter equals the diameter of the electrode. Figures 5a, 5b illustrate the impact of the sample capacitance on the sheath potential and IED at ICP power of 1000 W and 300 W, respectively. The sample capacitance was varied by changing the thickness of the fused silica samples, and the utmost right point corresponds to the 500 lm thickSiwafer.
All the values( sheath potential, ion energy, and IED) plummet with the decreased capacitance( increased thickness) and both the potential and the maximum ion energy exhibit a power law dependence on it, such as y = ax b + c, where y is ion energy or sheath potential, x represents the sample capacitance, and a, b, and c are fitting coefficients. This effect is more pronounced at higher ICP power.
Figure 6 shows how the maximum ion energy changes for samples with different thicknesses. It is interesting that while for Si wafer( C sub = 7 nF) the ion energy rises with ICP power, this trend is reversed for SiO 2 sample with thickness h > 2 mm( C sub < 0.56nF).
Finally, Figure 7 shows that increasing the sample radius also increases the sheath potential and broadens the IED, due to a larger effective capacitance.
These findings suggest that sample geometry significantly affects ion dynamics and must be considered in the design of the etching experiments.
5 Etching model and comparison with experimental values
The etching process in fluorocarbon plasma discharge is governed by the balance between the deposition of CF x polymer layer and the material removal [ 3 ]. This process