J. Eur. Opt. Society-Rapid Publ. 21, 52( 2025) 207
with s( t) being a time-dependent sheath thickness.
The following differential-algebraic system of equations( DAE) is formed by the EEC:
8
><
>: � dV ½1Š sub ðC ½1Š dt dV ½2Š
sub dt
½1Š dV sub dt s þ C eff Þ� dV 3 dt ðC ½2Š s þ C ½2Š
C eff � c Þ�dV 3 dt
½2Š dV sub
C ½2Š dt
C eff ¼ I ½1Š i � I ½1Š e
� V ½1Š sub
C ½2Š c c þ dV 3 dt
¼ I ½2Š i
ðC eff þ C ½2Š c
� I ½2Š e
� V ½2Š sub dC ½1Š
s dt
dC ½2Š
s dt
þ C b Þ¼ dV RF
C b dt
;
ð11Þ
where C c is the capacitance of the Si carrier wafer. The upper script [ 1 ] represents the path through the sample, and [ 2 ] is for the path through the open electrode covered by the Si carrier wafer. A combination of the carrier wafer and the sample is represented as capacitors in series with the effective capacitance C eff:
C eff ¼
C subC ½1Š c
C sub þ C ½1Š c
; ð12Þ
where C sub is the substrate capacitance, C ½1Š c is the capacitance of the carrier under the sample computed according to equations( 13a)–( 13c).
C sub ¼ e SiO 2 e 0 A sub h sub
; ð13aÞ
C ½1Š c
C ½2Š c
¼ e Sie 0 A sub h c
; ð13bÞ
¼ e Sie 0 A c h c
; ð13cÞ
where h sub and h c are thicknesses of the substrate and carrier wafer respectively.
The model is solved iteratively until the solution converges. At first, constant ion current I i ð0; tÞ ¼eAu B n p and constant sheath sðtÞ ¼I RF = en p x RF A are assumed and the DAE system( 11) is solved. Then equations( 2)–( 4) are solved with the obtained sheath potential V sub ðtÞ. After that, the DAE system( 11) is solved with new values for ion and electron currents and sheath thickness.
Generally speaking, finding the sheath-plasma boundary is not trivial. Godyak [ 25 ] suggested that the electric field at the sheath-plasma boundary is non-zero and equals EðxÞ ¼ k BT e ek D with Debye length k D: k D ¼ e 1 = 2
0k B T e: ð14Þ n p e 2
Riemannn [ 26 ] and Kaganovich [ 27 ] showed that the sheath boundary proposed by Godyak lies deep in the sheath. We define the sheath thickness s( t) as the position where the electric field reaches: dV ðxÞ EðxÞ ¼� ¼ k BT e
: dx 10ek D ð15Þ
We use MATLAB Ò ode23t solver for the DAE system( 11). PDEs( 3), and( 4) are solved by the method of lines with the finite difference in the space domain and MATLAB Ò ode23 solver in the time domain. Equation( 1) was solved with the MATLAB Ò bvp4c solver at each time step.
4 Simulation results
We simulate a carbon-fluorine discharge, assuming the presence of only CF 3 + ions. A uniform electron temperature k B T e = 3 eV was used( from the machine datasheet). Plasma density n 0 = aP coil was modeled as a linear function of the ICP power P coil, wherea is the slope coefficient [ 28 ]. The maximum plasma density n 0 = 5 10 17 m �3 was taken from the datasheet of the device and corresponds to the maximum P coil = 1200 W. RF frequency of the biased electrode f RF = 13.56 MHz and the driving voltage V RF was adjusted for different P coil to ensure that desired DC bias V DC is reached in the absence of the sample.
As an example, we show results for a SiO 2 substrate with radius r = 50 mm( half of the diameter of the electrode) and thickness h = 2 mm. Figure 3a shows calculated waveforms for the voltage across the sheath. As expected, the waveform shape is close to the half-rectified sinusoid [ 29 ]. Nevertheless, the potential drop in the sheath over the substrate is much smaller than that over the open part of the electrode.
Figures 3b and 3c illustrate current waveforms for the sample path, and for the electrode covered by the carrier wafer, respectively. During the negative half-cycle of the RF signal, the electron current is effectively zero, and ions are accelerated towards the sample with a delay due to their inertia. The plasma sheath responds to the current imbalance by increasing the displacement current. While I RF approaches zero, the displacement current becomes negative to balance the ion current since the potential is too high and the electron current is still zero. During the positive part of the RF cycle, electrons react immediately to the positive current imbalance, and the electron current rises instantly. This results in sheath collapse, and the displacement current approaches zero. Numerical calculations cause noise in the displacement current due to strong oscillations
dC sðtÞ dt
of the V w ðtÞ part in equation( 9) during the plasma sheath collapse.
Solution of the ion conservation equations allows us to obtain the instantaneous ion energy as:
E ion ðÞ¼ t m iu 2 i ðtÞ; ð16Þ 2
and compute ion energy distribution( IED)( Fig. 3d). The IED for the substrate is shifted towards lower energies with a narrower peak separation E sub ion = 93eVandEtable ion e = 143 eV.
This difference is explained by the reduced sample capacitance, which limits charge accumulation and reduces the displacement current required to balance the sheath. This results in a smaller potential drop and a weaker electric field, reducing ion acceleration. Correspondingly, ion velocity and density near the substrate are shown in