JEOS RP ISSN02 | Página 154

J. Eur. Opt. Society-Rapid Publ. 21, 45( 2025) 149
Fig. 5. results for the simulations of a monocyte with LDs( Visualization 3).( a) Isolevel. From this visualization, the size and the positioning of the LDs can be seen, compared to the overall cell;( b) yz cut of the simulated 3D RI distribution. The non uniform distribution of RI into the LD can be noticed;( c) Histograms of the sphericity index, average RI and standard deviation values are evaluated for the LDs in a population of 50 monocytes. l = mean value. r = standard deviation. EM = External membrane, C = Cytoplasm, N = Nucleus, LD = Lipid Droplets. For each cell, the isolevels’ thresholds for the visualization are set with respect to the maximum value of the simulated RI profile.
1.360 and standard deviation 0.008. Figure 6a presents an isolevel and a peripheral yz slice from the cell, where the asymmetry of the cell’ s external shell can be noted, together with the placement of the vacuoles and of their non-uniform RI distribution.
The results for the last case( Simulation 4) are reported in Figure 6b. In this case monocytes with 5 vacuoles and multiple lysosomes were modelled( 10 – 13). The RI values of the vacuoles are set up as in Simulation 3 and their equivalent radius is 1 lm. The RI values of the lysosomes are drawn from a Gaussian distribution with mean 1.46 and standard deviation 0.008 as reported in [ 19 – 21 ], while their equivalent diameter is drawn from a Gaussian distribution of mean 0.6 and standard deviation 0.3, as reported in [ 19 – 21 ]. Figure 6b depicts an isolevel and an xz slice of a simulated monocyte with 13 lysosomes, where the difference in size between lysosomes and vacuoles can be noted.
3.1 Simulation of digital holograms
As mentioned in the previous sections, having a tool allowing to simulate a ground truth distribution of refractive index is useful to tune all the steps of an optical imaging pipeline. In particular, it is possible to numerically reproduce the digital holograms by simulating the interference between an object beam propagating through the simulated RI distribution [ 43 ] and a reference beam. The results are