IEEE Newsletter - University of Peradeniya Volume 2 (March 2019) | Page 27

REMODELLED AND MODERNIZED T he old high voltage laboratory was a two-storied building which contained mainly a high voltage laboratory and had laboratories allocated for Non-destruc ve Tes ng, Sample Prepara on, Material lab and Open Test Area. Also, a separate place was allocated as an exhibi on area for regular visitors to understand the power genera on, transmission and distribu on systems. The main AC transformer that was available in the lab was a 250kV, 15kVA AC transformer made by TOKYO TRANSFORMER Company Ltd. which was used for flashover tests on high voltage apparatus. To facilitate chemical tes ng, a Transformer Dissolve Gas Analyzer made by SHIMADSHU was used for analysis of dissolved gases in transformer oil. It included Rapid oven cooling and a self-diagnos c func on to prevent failure and a gas-saver func on to save carrier gas consump on. The modernized new lab is divided into seven tes ng areas to conduct different tests independently. The divisions are; The Impulse tes ng lab, AC tes ng lab, DC tes ng lab, PD tes ng lab, EMC lab, Insulator Tes ng Area and the Clima c chamber. An open space is also used for AC tes ng. For DC Tes ng Facili es, a 100 kV DC Generator is included in the proposal. This facility will be used for DC tes ng with low leakage measurements which may even contain fluctua ng line voltages with reversible polarity. It should be ideal for field tes ng (compact and lightweight). An EMC lab is proposed to be built with fully Aluminium side walls, roof and floor. It can be used for tes ng purposes such as Electro- Magne c tes ng and Electrosta c tes ng. As for non-destruc ve tes ng facili es, a Frequency Domain Dielectric Spectroscopy (FDS) is allocated for automated measurement and analysis of moisture content, tan delta/power factor and oil conduc vity, including individual temperature correc on (ITC) of tan delta/power factor and oil conduc vity, a Frequency Response Analyzer (FRA) to detect transformer winding movements and mechanical failures due to mechanical shock, transporta on or short circuits, a Capacitance & Tan Delta Tester for capacitance, dissipa on/ power factor tes ng, a Combina on Wave Simulator to generate high currents as lightening is a high current surge in which the surge voltage could be up to 8kV and the surge current can be as high as 4kA, etc. There is also an outdoor tes ng area which includes a Weather Sta on which can diagnose the weather condi ons that may be important for high voltage tes ng, an Insulator Aging System which is planned to be placed in the outdoor tes ng area to provide exposure to air for aging. Shan Wijesinghe Electrical and Electronic Engineering University of Peradeniya IEEE Newsletter University of Peradeniya Improvements in the new PROF. W.P. JAYASEKARA HIGH VOLTAGE LABORATORY PAGE 25