GAS & ELECTRIC
THERMOSTATS
Robertshaw ® 5300 and 5210 Electric Thermostats (continued)
TEMP.
RANGE
ITEM No.
Legend for
Comments
A With auxiliary switch
B Screwdriver adjustment
C Dipsealed
D Has panel nut
E Uni kit
F 1 ⁄ 4 " stuffing box
G 3 ⁄ 8 " stuffing box
H Fiberglass cap shield
I Pointer-type adjustment
J 2" break-off shaft
K Curved bulb
Legend for
Replacement
Dials
ITEM
TEMP.
No. RANGE
L 130-1001 1 to 10
M 130-1002 60° to 250°F
N 130-1004 100° to 450°F
O 220-1171 175° to 500°F
P 187-1101 200° to 500°F
Q 130-1007 200° to 400°F
R 130-1008 200° to 550°F
S 130-1009 300° to 700°F
T 168-1194 230° to 375°F
U 183-1142 100° to 200°F
V 130-1005 100° to 550°F
W 171-1106 250° to 600°F
X 501-1016 90° to 190°F
Y 180-1053 60° to 200°F
CAP.
LENGTH
BULB SIZE
BRACKET
TYPE
DIAL
INCLUDED
REPLACEMENT
DIAL
KNP-TYPE
(SPST, direct acting, contacts open on temperature rise, used on applications that may reach
1000°F, with positive “Off”)
5
⁄ 32 " x 8 1 ⁄ 4 "
36"
#5
N
–
L
202-1125 250° to 950°F
KP-TYPE
(model K with positive “Off” position)
1
⁄ 4 " x 12"
36"
201-1096 125° to 325°F
5
⁄ 16 " x 7 1 ⁄ 4 "
30"
297-1013 120° to 550°F
5
⁄ 16 " x 9"
36"
501-1001 90° to 190°F
KX-TYPE
228-1182
230-1002
240-1036
187-1108
164-1046
166-1111
228-1188
227-1050
227-1138
175-1058
228-1091
162-1094
230-1003
(SPST, breaks on
100° to 450°F
100° to 450°F
100° to 450°F
140° to 550°F
150° to 475°F
175° to 500°F
175° to 550°F
200° to 400°F
200° to 400°F
200° to 400°F
200° to 400°F
200° to 500°F
550°F Fixed
KXL-TYPE
175-1060
#1
#1
#1
N
N
N
–
–
–
temperature rise, used on low current pilot duty circuits, 120/277 volt AC)
3
⁄ 16 " x 11 5 ⁄ 8 "
36"
#1
N
C
3
⁄ 16 " x 12 5 ⁄ 8 "
36"
#1
N
C
3
24"
⁄ 16 " x 12"
#1
N
–
3
⁄ 16 " x 11 5 ⁄ 8 "
36"
#1
N
–
3
⁄ 16 " x 11"
#1
N
–
48"
3
⁄ 16 " x 11 5 ⁄ 8 "
60"
#1
Y
–
3
⁄ 16 " x 11 5 ⁄ 8 "
60"
#1
N
–
5
⁄ 16 " x 5 1 ⁄ 8 "
24"
#1
Y
G
5
⁄ 16 " x 5 1 ⁄ 2 "
24"
#1
Y
G
3
⁄ 8 " x 5 5 ⁄ 8 "
36"
#1
N
C, F
1
⁄ 4 " x 12 1 ⁄ 8 "
48"
#1
N
C, G
3
⁄ 16 " x 11 3 ⁄ 4 "
36"
#1
Y
–
3
⁄ 16 " x 11 1 ⁄ 2 "
36"
#1
N
C
(model KX, meets UL requirement as a Limit Control)
3
⁄ 16 " x 5 7 ⁄ 8 "
435°F Fixed
36"
#1
L
V
X
N
N
–
R
L
R
R
Z
Z
Q
Q
P
–
N C, F –
#1
#6
#5 N
Y
Y –
E
– –
R
Q
#1 N – O
KXP-TYPE
(model KX, has positive “Off” added)
3
⁄ 16 " x 11"
48"
170-1163 100° to 450°F
3
⁄ 16 " x 11 5 ⁄ 8 "
60"
166-1111 175° to 550°F
3
⁄ 16 " x 6 1 ⁄ 2 "
24"
202-1135 200° to 400°F
KXT-TYPE
(model L161136)
36"
220-1157 175° to 500°F
RX-TYPE
168-1194
194-1080
228-1192
228-1210
169-1040
196-1060
173-1152
⁄ 16 "
3
x 12 1 ⁄ 4 "
(millivolt direct current, hermetically sealed reed switches, rated for .67 amp at 5 volt DC)
5
⁄ 16 " x 4 3 ⁄ 4 "
200° to 375°F
24"
#1
N
F
3
⁄ 8 " x 5 3 ⁄ 8 "
200° to 375°F
36"
#1
N
G
3
⁄ 8 " x 5 5 ⁄ 8 "
#1
N
G
200° to 400°F
24"
5
⁄ 16 " x 4 7 ⁄ 8 "
200° to 400°F
24"
#1
N
G
3
⁄ 8 " x 7 3 ⁄ 4 "
200° to 400°F
30"
#1
N
H
3
⁄ 8 " x 5 1 ⁄ 8 "
200° to 400°F
36"
#1
N
F
3
⁄ 16 " x 11 5 ⁄ 8 "
200° to 450°F
24"
#1
N
–
Z 227-1058 200° to 400°F
Aa 194-1106 200° to 375°F
Bb 229-1174 150° to 500°F
Cc 173-1153 200° to 450°F
Dd 130-1061 200° to 400°F
Ee 130-1003 100° to 200°F
Ff 160-1303 200° to 450°F
516
COMMENTS
fmponline.com
T
Q
Q
Q
–
Q
Cc