FMP-COMERSAMX CATALOGO FMP | Page 574

GAS & ELECTRIC THERMOSTATS Robertshaw ® 5300 and 5210 Electric Thermostats (continued) TEMP. RANGE ITEM No. Legend for Comments A With auxiliary switch B Screwdriver adjustment C Dipsealed D Has panel nut E Uni kit F 1 ⁄ 4 " stuffing box G 3 ⁄ 8 " stuffing box H Fiberglass cap shield I Pointer-type adjustment J 2" break-off shaft K Curved bulb Legend for Replacement Dials ITEM TEMP. No. RANGE L 130-1001 1 to 10 M 130-1002 60° to 250°F N 130-1004 100° to 450°F O 220-1171 175° to 500°F P 187-1101 200° to 500°F Q 130-1007 200° to 400°F R 130-1008 200° to 550°F S 130-1009 300° to 700°F T 168-1194 230° to 375°F U 183-1142 100° to 200°F V 130-1005 100° to 550°F W 171-1106 250° to 600°F X 501-1016 90° to 190°F Y 180-1053 60° to 200°F CAP. LENGTH BULB SIZE BRACKET TYPE DIAL INCLUDED REPLACEMENT DIAL KNP-TYPE (SPST, direct acting, contacts open on temperature rise, used on applications that may reach 1000°F, with positive “Off”) 5 ⁄ 32 " x 8 1 ⁄ 4 " 36" #5 N – L 202-1125 250° to 950°F KP-TYPE (model K with positive “Off” position) 1 ⁄ 4 " x 12" 36" 201-1096 125° to 325°F 5 ⁄ 16 " x 7 1 ⁄ 4 " 30" 297-1013 120° to 550°F 5 ⁄ 16 " x 9" 36" 501-1001 90° to 190°F KX-TYPE 228-1182 230-1002 240-1036 187-1108 164-1046 166-1111 228-1188 227-1050 227-1138 175-1058 228-1091 162-1094 230-1003 (SPST, breaks on 100° to 450°F 100° to 450°F 100° to 450°F 140° to 550°F 150° to 475°F 175° to 500°F 175° to 550°F 200° to 400°F 200° to 400°F 200° to 400°F 200° to 400°F 200° to 500°F 550°F Fixed KXL-TYPE 175-1060 #1 #1 #1 N N N – – – temperature rise, used on low current pilot duty circuits, 120/277 volt AC) 3 ⁄ 16 " x 11 5 ⁄ 8 " 36" #1 N C 3 ⁄ 16 " x 12 5 ⁄ 8 " 36" #1 N C 3 24" ⁄ 16 " x 12" #1 N – 3 ⁄ 16 " x 11 5 ⁄ 8 " 36" #1 N – 3 ⁄ 16 " x 11" #1 N – 48" 3 ⁄ 16 " x 11 5 ⁄ 8 " 60" #1 Y – 3 ⁄ 16 " x 11 5 ⁄ 8 " 60" #1 N – 5 ⁄ 16 " x 5 1 ⁄ 8 " 24" #1 Y G 5 ⁄ 16 " x 5 1 ⁄ 2 " 24" #1 Y G 3 ⁄ 8 " x 5 5 ⁄ 8 " 36" #1 N C, F 1 ⁄ 4 " x 12 1 ⁄ 8 " 48" #1 N C, G 3 ⁄ 16 " x 11 3 ⁄ 4 " 36" #1 Y – 3 ⁄ 16 " x 11 1 ⁄ 2 " 36" #1 N C (model KX, meets UL requirement as a Limit Control) 3 ⁄ 16 " x 5 7 ⁄ 8 " 435°F Fixed 36" #1 L V X N N – R L R R Z Z Q Q P – N C, F – #1 #6 #5 N Y Y – E – – R Q #1 N – O KXP-TYPE (model KX, has positive “Off” added) 3 ⁄ 16 " x 11" 48" 170-1163 100° to 450°F 3 ⁄ 16 " x 11 5 ⁄ 8 " 60" 166-1111 175° to 550°F 3 ⁄ 16 " x 6 1 ⁄ 2 " 24" 202-1135 200° to 400°F KXT-TYPE (model L161136) 36" 220-1157 175° to 500°F RX-TYPE 168-1194 194-1080 228-1192 228-1210 169-1040 196-1060 173-1152 ⁄ 16 " 3 x 12 1 ⁄ 4 " (millivolt direct current, hermetically sealed reed switches, rated for .67 amp at 5 volt DC) 5 ⁄ 16 " x 4 3 ⁄ 4 " 200° to 375°F 24" #1 N F 3 ⁄ 8 " x 5 3 ⁄ 8 " 200° to 375°F 36" #1 N G 3 ⁄ 8 " x 5 5 ⁄ 8 " #1 N G 200° to 400°F 24" 5 ⁄ 16 " x 4 7 ⁄ 8 " 200° to 400°F 24" #1 N G 3 ⁄ 8 " x 7 3 ⁄ 4 " 200° to 400°F 30" #1 N H 3 ⁄ 8 " x 5 1 ⁄ 8 " 200° to 400°F 36" #1 N F 3 ⁄ 16 " x 11 5 ⁄ 8 " 200° to 450°F 24" #1 N – Z 227-1058 200° to 400°F Aa 194-1106 200° to 375°F Bb 229-1174 150° to 500°F Cc 173-1153 200° to 450°F Dd 130-1061 200° to 400°F Ee 130-1003 100° to 200°F Ff 160-1303 200° to 450°F 516 COMMENTS fmponline.com T Q Q Q – Q Cc