NEW
NEW
NEW
NEW
Joints
Penetrating Item ( s ) F-Rating T-Rating Movement Product System Number
JOINTS — HEAD-OF-WALL ( HW-D SERIES ) ( CONTINUED )
Concrete or CMU wall to Flat Concrete ( One Side Access ) ( Max . JW = 2 ”) Optional max 1 ”
Gypsum wall to concrete over fluted metal deck perpendicular ( top-of-wall ) ( Max JW = 1-1 / 2 ”)
Gypsum wall to concrete over fluted metal deck parallel ( top-of-wall ) ( Max JW = 1-1 / 2 ”)
Gypsum wall to concrete over fluted metal deck parallel ( top-of-wall ) ( Max JW = 1-1 / 2 ”)
2 Hr 12.5 % CP-606 HW-D-0825
1 or 2 Hr ◼
1 or 2 Hr ◼
1 or 2 Hr ◼
NEW Gypsum wall to flat concrete ( top-of-wall ) ( Max JW = 1-1 / 2 ”) 1 or 2 Hr ◼
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
Gypsum shaft wall to concrete over fluted metal deck perpendicular ( top-of-wall ) ( Max JW = 1 / 2 ”)
Gypsum shaft wall to concrete over fluted metal deck parallel ( top-of-wall ) ( Max JW = 1 / 2 ”)
Gypsum shaft wall to concrete over fluted metal deck with structural steel beam parralell to wall ( top-of-wall ) ( Max JW = 1 / 2 ”)
Gypsum wall to concrete over fluted metal deck parallel and perpendicular ( top-of-wall ) ( Max JW = 1 / 2 ”)
Gypsum wall to flat concrete ( top-of-wall ) ( Max JW = 15 / 16 ”) Post install of TTS
Gypsum wall to concrete over metal deck ( top-of-wall ) ( by Epic Metals ) ( Max JW = 3 / 4 ”)
Gypsum wall to concrete over fluted metal deck angled ( top-ofwall ) ( Max JW = 1-1 / 2 ”)
Gypsum shaft wall to flat concrete ( top-of-wall ) ( Nom . JW = 1 / 2 ” or 3 / 4 ”)
Gypsum wall assembly to concrete over fluted metal deck parallel and perpendicular flutes filled with fire proofing ( top-of-wall ) ( Max JW = 1-1 / 2 ”)
Gypsum wall assembly to concrete over fluted metal deck parallel and parallel ( top-of-wall ) ( Max JW = 1-1 / 2 ”)
Concrete or block wall to concrete floor joint ( top-of-wall ) ( Max JW = 3-1 / 2 ”)
Concrete or block wall to concrete floor joint ( top-of-wall ) ( Max JW = 3-3 / 4 ”)
Gypsum wall to concrete or concrete over metal deck ( Max JW = 3 ”) ( FireTrak )
Gypsum wall to concrete or concrete over metal deck ( Max JW = 3 ”) ( FireTrak )
Gypsum wall to concrete or concrete over metal deck ( Max JW = 3 ”) ( FireTrak )
Concrete or block wall to concrete over fluted metal deck ( top-of-wall ) ( Max JW = 3-1 / 2 ”)
Concrete wall to concrete over metal deck w / spray-on fireproofing completely filling flutes ( top-of-wall ) ( Max JW = 3-1 / 2 ”)
Concrete or block wall to concrete floor joint ( top-of-wall ) ( Max JW = 2 ”)
Concrete or block wall to concrete over fluted metal deck w / steel bracing ( top-of-wall ) ( Max JW = 3-1 / 2 ”)
Concrete or block wall to concrete floor w / steel bracing ( top-of-wall ) ( Max JW = 3-1 / 2 ”)
Concrete or block wall to concrete floor ( Max JW = 3-1 / 4 ”)
Gypsum wall perpendicular to fluted metal deck ( Max JW = 2-1 / 2 ”)
Gypsum wall parallel to fluted metal deck ( Max JW = 2-1 / 2 ”)
Gypsum wall to underside of flat concrete ( Max JW = 2-1 / 2 ”)
Block wall perpendicular / parallel to fluted metal deck ( Max JW = 2-1 / 2 ” or 1-1 / 2 ”)
Block wall to underside of flat concrete ( Max JW = 2-1 / 2 ”)
50 % or 66 %
50 % or 66 %
50 % or 66 %
50 % or 66 %
CFS-TTS MD
CFS-TTS MD
CFS-TTS MD
CFS-TTS MD
HW-D-0871
HW-D-0872
HW-D-0873
HW-D-0880
1 or 2 Hr ◼ 50 % CFS-TTS MD HW-D-0881
1 or 2 Hr ◼ 50 % CFS-TTS MD HW-D-0882
1 or 2 Hr ◼ 50 % CFS-TTS MD HW-D-0883
1 or 2 Hr ◼ 50 % CFS-TTS MD HW-D-0884
2 or 3 Hr ◼
50 % or 66 %
CFS-TTS
HW-D-0905
1 or 2 Hr ◼ 33 % CFS-SP WB , CP 620 HW-D-0906
1 or 2 Hr ◼
1 or 2 Hr
1 or 2 Hr ◼
1 or 2 Hr ◼
50 % or 66 %
50 % or 66 %
50 % or 66 %
50 % or 66 %
CFS-TTS MD
CFS-TTS
CFS-TTS MD
CFS-TTS MD
HW-D-0907
HW-D-0920
HW-D-0923
HW-D-0925
3 Hr 14 % CFS-S SIL GG HW-D-1008
2 Hr ◼ 7 % CP 606 HW-D-1009
1,2 or 3 Hr
1 , 2 or 3 Hr
1 , 2 or 3 Hr
100 %
100 %
100 %
CP 601s CFS-S SIL GG FS-ONE MAX
CP 601s CFS-S SIL GG FS-ONE MAX
CFS-SP WB FS-ONE MAX
HW-D-1011
HW-D-1012
HW-D-1020
2 Hr 14 % CFS-SP WB HW-D-1037
2 Hr
7 % or 14 %
CFS-SP WB
HW-D-1041
4 Hr 12.5 % CFS-S SIL GG HW-D-1042
2 Hr 14 % CFS-SP WB HW-D-1044
2 Hr 14 % CFS-SP WB HW-D-1045
3 Hr 25 % CFS-SP WB HW-D-1058
1 or 2 Hr 40 % CFS-SP WB HW-D-1066
1 or 2 Hr 40 % CFS-SP WB HW-D-1067 1 or 2 Hr 40 % CFS-SP WB HW-D-1068
1 or 2 Hr
40 % or 50 %
CFS-SP WB
HW-D-1069
1 or 2 Hr 40 % CFS-SP WB HW-D-1070
CLICK CATEGORY INFO BELOW :
Blank Openings Metallic Penetrants Non-Metallic Pipes * Cables / Cable Trays Insulated Pipes
Miscellaneous Electrical ( Busway )
Miscellaneous Mechanical / Ducts
Mixed Penetrating Items *
Blank Openings Metallic Penetrants Non-Metallic Pipes * Cables Cable Trays Insulated Pipes
Miscellaneus Electrical ( Busway )
Miscellaneous Mecahnical / Ducts *
Mixed Penetrating Items *
Blank Openings
Metallic Penetrations
Non-Metallic Pipes * Cables Insulated Pipes
Miscellaneous Mechanical / Duct Penetrations
Mixed Penetrating Items *
Metallic Penetrations
Non-Metallic Pipes * Cables Insulated Pipes
Miscellaneous Mechanical / Duct Penetrations
Mixed Penetrating Items *
Bottom of Wall ( BW-S Series )
Continuity Head-of- Wall ( CJ-D Series )
Floor-to-Floor ( FF-D Series )
Floor-to-Wall ( FW-D Series )
Intertek Series ( ASTM E 1966 )
Head-of-Wall ( HW-D Series )
Head-of-Wall ( HW-S Series )
Wall-to-Wall ( WW-D Series )
Wall-to-Wall ( WW-S Series )
Perimeter Fire Barrier Joints ( Curtain Wall ) – ASTM E2307
Joints Steel-Framed Floors Wood-Framed Floors Framed ( Gypsum ) Walls Concrete Floors / Walls 49
Head-of-Wall ( HW-D Series ) ( continued ) ➜