Fire Code of the Philippines Ebook - SafetySignsPH.com Fire Code of the Philippines eBook - SafetySignsPH | Page 151

Section of the Chapter governing such other occupancy shall apply. B. Occupant Load 1. The occupant load of educational buildings or any individual storey or section thereof for the purpose of determining exits shall not be less than one person for each one and nine -tenths square meters (1.9 m 2 ) of net classroom area or four and six-tenths (4.6) square meters of net area of shops, laboratories, and similar vocational rooms. In dry nurs- eries where sleeping facilities are provided, the occupant load shall be not less than one person for each three and three tenths square meters (3.3 m 2 ). 2. The occupant load of an area having fixed seats shall be determined by the number of fixed seats installed. Required aisle space serving the fixed seats shall not be used to increase the occupant load. 3. The occupant load of individual lecture rooms, gymnasiums, or cafeterias used for assembly purposes of more than fifty (50) persons shall be determined in accordance with Section 10.2.8.1 of this IRR. SECTION 10.2.9.2 EXIT DETAILS A. Capacity of Exits Capacity of means of egress shall be in accordance with Section 10.2.5.2 para ā€œCā€ of this IRR. B. Minimum Number of Exits 1. Every room or space with a capacity of fifty (50) or more persons or over ninety three square meters (93 m 2 ) in area shall have at least two (2) doorways as remote from each other as practicable. Such doorways shall provide access to separate exits, but, where egress is through corridors, shall open upon a common corridor leading to separate exits in opposite directions. 2. Not less than two separate exits shall be provided on every storey and accessible from every part of every storey and mezzanine. C. Travel Distance to Exits Travel distance to an exit from any point in a building without an approved, supervised automatic sprinkler system shall not exceed forty six meters (46 m), and shall not exceed sixty one meters (61 m) in any building protected throughout by an approved, supervised automatic sprinkler system. 135