Field Installation and Service Manual IMS106 | Page 3
Step 3
Rip Filler to Fit
(With Simple, Tapered and Complex Reveal Space Conditions)
onditions)
Step 3A - Rip Filler to Fit: Simple Wall
Condition
Space between wall and cabinet is parallel
106
3A.1 Simple
If the dimensions along the space to be fi lled are within 1/16”, transfer
the largest measurement to the table saw and rip the scribe material to
width with fi nished side up.
Step 3B - Rip Filler to Fit: Tapered Wall Condition
Wall is straight but the fi ller space dimension is different from top to
bottom.
3B.1 Tapered
In a condition where the wall is straight but not plumb, the space to
be fi lled will be in the shape of a taper.
Identify the dimensions required for a fi ller to fi t snug in the space.
Wall Filler- Scribing to a Tapered Wall Condition
Transfer the smallest measured
dimension to the face of the fi ller at
the end that will enter the saw fi rst.
Confi rm that the mark is visible.
Make the wider dimension on the
opposite end.
If needed, mark a straight line be-
tween the two points.
Tapered wall condition
at filler space
2-3/4”
2-3/4”
Wall
Cabinet
3B.2 Tapered
Wall
2-1/2”
©2017 PCS Professional Cabinet Solutions. All Rights Reserved.
Scribe material
measured and
marked to fit a
tapered filler
space between
a wall and
a wall cabinet
2-1/2”
Section 1: IMS 106
3