PROJECT INCORPORATING COLD CHAIN The ethylene gas concentration is measured in the room via the PLC and ethylene sensors. From this value ethylene is supplied to the rooms through solenoid coils at each room being supplied gas from a bank of gas bottles located at the plant room. An interesting fact is that when the bananas begin to ripen, they release ethylene gas themselves and this system will monitor the rising levels and ventilate fresh air into the rooms to hold a constant gas level and hence also ventilate out other deleterious byproduct gasses such as CO 2 . The fresh air system mentioned above consists of ducting in and out of the room with non-return dampers to seal air tight until they are required, when the fans will come on and vent fresh air into the room while exhausting the ethylene and CO 2 -rich air from the room. ALL ABOUT CONTROL The ripening room control system uses Eliwell Free Advance programmable logic controllers (PLCs), explains Ben Milne of Keystar. Its standard ripening application is configurable to modulate heating and cooling, ventilation based on ethylene/ CO 2 levels, humidity control and ethylene modulation. Using up to four PT1000 Class A/NTC spiked sensors, the average 14 JoJo tank holding cooling system water. www.coldlinkafrica.co.za Canvas air curtains dropping from stainless steel coils. COLD LINK AFRICA • June 2019