Cold Link Africa Jul/Aug 2016 Vol 1 No 6 | Página 31
FEATURE
INCORPORATING COLD CHAIN
Validation of performance
efficiency will reduce power bill
By John Ackermann
Klas Berglöf of ClimaCheck, Sweden, recently delivered presentations
around the country to demonstrate the difference between efficiency and
performance in HVAC&R systems.
H
#ClimaCheck
igh electricity bills are of growing
consumption (efficiency) of HVAC&R
annum can be achieved without any
concern to all operators of HVAC&R
systems, while maintaining the desired
major modifications being done to the
installed but not correctly set up, and
installations.
air or chilled water temperature. The
plant,” says Berglöf. He claims that in
in some cases not needed at all.
HVAC&R systems can be found
•
Variable frequency drive (VFD)
temperature is accepted as being within
supermarkets, savings are between 20%
anywhere from supermarkets and
the range, but just how much electricity is
and 30%; ice rinks between 20% and 40%;
Most of the problems mentioned by Berglöf
hospitals, to breweries and fruit farms,
being consumed?
and in industrial applications, heat pumps
appear to be obvious and yet are allowed
and air conditioning between 10% and
to continue. He gave his views as to why
plant performance inefficiency persists.
wineries, food processing factories and
After many years of research, the
ice rinks, distribution centres, and even
ClimaCheck system has been developed
30%. “Even an annual saving of only 10%
pharmaceutical production plants — in
to assess the actual energy efficiency
has a major impact on the bottom line
fact, HVAC&R is everywhere. Globally,
(coefficient of performance) at any
of any business; at 30% — as we have
cause,” he says. “Some of the plants that
HVAC&R utilises about 20% of all electricity
particular time based on measured
found in many supermarkets — the savings
we have checked have operated for 10
consumption and many plants consume
operating parameters. With his years of
are even more significant. Any saving in
or 20 years at low performance efficiency
far more electricity than needed.
experience, Berglöf can diagnose the
electricity is also a reduction in carbon
because of not being commissioned
“Poor commissioning is a common
assessment and recommend remedial action
emission and will impact on the carbon
correctly. Plants are checked against
supermarket fridge or office is checked
to improve coefficient of performance (COP)
footprint.”
specification and no attention given to
just as the chilled water temperature in a
and reduce power usage.
The air temperature in a cold store,
optimisation. Another common problem
processing plant is tested, and if incorrect,
Commissioning of plant sets the pace
is not fixing something that isn’t broken
a service contractor is called in to attend
Berglöf named the most commonly found
when it comes to the compressors, pumps
to the problem. But a contractor is never
problems that result in a loss of energy
and fans. A compressor may need valve
performance (in no particular order of
replacement to regain performance
importance) as:
efficiency, but is allowed to operate until it
•
Refrigerant shortage or over charge;
fails completely. This ‘run to fail’ approach
•
Compressor damage or wear;
is quite common and dramatically
•
Control problems;
increases the total life cycle cost of a
•
Polluting of heat exchangers;
given system.”
•
Flow problems in secondary media
requested or a complaint lodged with the
service department when the electricity
consumption is excessive. Most plant
operators and many service contractors
accept the electricity consumption as
a given, and direct all their attention
to attaining the required temperature.
The difference between efficiency and
The fundamental issue in
the HVAC&R industry is that
system efficiency is no‑one’s
responsibility; but not only
that, until now it was nearly
impossible to measure.
performance is often misunderstood.
(too much or too little air/water/brine);
•
Fan or pump under performance;
“With our ClimaCheck system, we have
•
Incorrectly set control sensors;
Not just about temperature
assessed many plants in different countries
•
System components changed or
Berglöf’s presentations pointed to the
from the east to the west. We found
upgraded without a full system
many factors that influence the electricity
that energy savings from 10% to 40% per
review; and
1
1. The presentation at SAIRAC Cape Town
was well supported.
2. From left: Danie van Zyl, Klas Berglöf,
and Kevin Schlemmer at the Cape
Town premises of CoolCheck.
2
COLD LINK AFRICA • July | August 2016
www.coldlinkafrica.co.za
31