Cold Link Africa Jul/Aug 2016 Vol 1 No 6 | Página 31

FEATURE INCORPORATING COLD CHAIN Validation of performance efficiency will reduce power bill By John Ackermann Klas Berglöf of ClimaCheck, Sweden, recently delivered presentations around the country to demonstrate the difference between efficiency and performance in HVAC&R systems. H #ClimaCheck igh electricity bills are of growing consumption (efficiency) of HVAC&R annum can be achieved without any concern to all operators of HVAC&R systems, while maintaining the desired major modifications being done to the installed but not correctly set up, and installations. air or chilled water temperature. The plant,” says Berglöf. He claims that in in some cases not needed at all. HVAC&R systems can be found • Variable frequency drive (VFD) temperature is accepted as being within supermarkets, savings are between 20% anywhere from supermarkets and the range, but just how much electricity is and 30%; ice rinks between 20% and 40%; Most of the problems mentioned by Berglöf hospitals, to breweries and fruit farms, being consumed? and in industrial applications, heat pumps appear to be obvious and yet are allowed and air conditioning between 10% and to continue. He gave his views as to why plant performance inefficiency persists. wineries, food processing factories and After many years of research, the ice rinks, distribution centres, and even ClimaCheck system has been developed 30%. “Even an annual saving of only 10% pharmaceutical production plants — in to assess the actual energy efficiency has a major impact on the bottom line fact, HVAC&R is everywhere. Globally, (coefficient of performance) at any of any business; at 30% — as we have cause,” he says. “Some of the plants that HVAC&R utilises about 20% of all electricity particular time based on measured found in many supermarkets — the savings we have checked have operated for 10 consumption and many plants consume operating parameters. With his years of are even more significant. Any saving in or 20 years at low performance efficiency far more electricity than needed. experience, Berglöf can diagnose the electricity is also a reduction in carbon because of not being commissioned “Poor commissioning is a common assessment and recommend remedial action emission and will impact on the carbon correctly. Plants are checked against supermarket fridge or office is checked to improve coefficient of performance (COP) footprint.” specification and no attention given to just as the chilled water temperature in a and reduce power usage. The air temperature in a cold store, optimisation. Another common problem processing plant is tested, and if incorrect, Commissioning of plant sets the pace is not fixing something that isn’t broken a service contractor is called in to attend Berglöf named the most commonly found when it comes to the compressors, pumps to the problem. But a contractor is never problems that result in a loss of energy and fans. A compressor may need valve performance (in no particular order of replacement to regain performance importance) as: efficiency, but is allowed to operate until it • Refrigerant shortage or over charge; fails completely. This ‘run to fail’ approach • Compressor damage or wear; is quite common and dramatically • Control problems; increases the total life cycle cost of a • Polluting of heat exchangers; given system.” • Flow problems in secondary media requested or a complaint lodged with the service department when the electricity consumption is excessive. Most plant operators and many service contractors accept the electricity consumption as a given, and direct all their attention to attaining the required temperature. The difference between efficiency and The fundamental issue in the HVAC&R industry is that system efficiency is no‑one’s responsibility; but not only that, until now it was nearly impossible to measure. performance is often misunderstood. (too much or too little air/water/brine); • Fan or pump under performance; “With our ClimaCheck system, we have • Incorrectly set control sensors; Not just about temperature assessed many plants in different countries • System components changed or Berglöf’s presentations pointed to the from the east to the west. We found upgraded without a full system many factors that influence the electricity that energy savings from 10% to 40% per review; and 1 1. The presentation at SAIRAC Cape Town was well supported. 2. From left: Danie van Zyl, Klas Berglöf, and Kevin Schlemmer at the Cape Town premises of CoolCheck. 2 COLD LINK AFRICA • July | August 2016 www.coldlinkafrica.co.za 31