Civil Insight: A Technical Magazine Volume 3 | Page 56

Shrestha P. et al. Civil Insight (2019) 51-56 Seti Hydropower Project, the ƒ -value within area of 300km of the dam site is found to be 3.48, and the „ - value is 0.83. Similarly, for other 12 source zones, seismicity parameters were determined. In the study, the „ -value was kept the same throughout all seismic source zones considering „ -value depends upon the tectonic characteristics of the region. Recommendations Future seismic events at the dam site could be predicted on carring out further researches using these seismicity parameters. These parameters are also significant for performing the probabilistic seismic hazard analysis. References Ambraseys, N., & Douglas, J. (2004). Magnitude Calibration of North Indian Earthquakes. Geophysical Journal International, 165-206. Gardner, J., & Knopoff, L. (1974). Is the Sequence of Earthqakes in Sorthern California, with Aftershocks Removed, Poissionian? Bulletion of the Seismological Society of America, 1363-1367. Gutenberg, B., & Richter, C. (1944). Frequency of earthquakes in California. Bulletin of the Seismological Society of America, 1985-1988. Gutenberg, B., & Richter, C. (1956). Earthquake Magnitude, Intensity, Energy and Acceleration. Bulletin of the Seismological Society of America, 105-145. Hanks, T., & Kanamori, H. (1994). A Moment Magnitude Scale. Journal of Geophysical Research, 2348- 2350. JICA. (2007). Upgrading Feasibility Study on Upper Seti (Damauli) Storage Hydroelectric Project in Nepal. Japan International Corporation Agency, Electric Power Development Co., Ltd., Nippon Koei Co., Ltd. Retrieved from http://open_jicareport.jica.go.jp/643/643/643_116_11858982.html Kijko, A., & Smit, A. (2012). Extension of the Aki-Utsu b-value Estimator for Incomplete Catalogs. Bulletin of the Seismological Society of America, 1283-1287. Kramer, S.L. (2007). Geotechnical Earthquake Engineering. Chennai, Tamil Nadu: Pearson India Education Services Pvt. Ltd. Liu, R., Chen, Y., Ren, X., Xu, Z., Sun, L., & Yang, H. (2007). Comparison Between Different Earthquake Magnitudes Determined by China Sesimograph Networks. Acta Seismologica Sinica, 467-476. MATLAB (Version R2015a) [Computer software]. (2015). The MathWorks, Inc. Available from https://www.mathworks.com/products/matlab.html Thapa, D., & Wang, G. (2013). Probabilistic Seismic Hazard Analysis in Nepal. Earthquake Engineering and Engineering Vibration, 577-586. Wang, S., Wang, J., Wu, Q., Gao, A., & Gao, M. (2010). The Empirical Relationship Between ML and Ms Based on Bulletin of Sesimological Observations of Chinese Stations. Earthqukae Research in China, 14- 22. 56