Ariston Manual Products AQ5NI24JVS | Page 9

Location Requirements Electrical Requirements WARNING WARNING Electrical Shock Hazard Explosion Hazard Plug into a grounded (earthed) outlet. gasoline, away from refrigerator. Do not remove ground prong. Do not use an adapter. Do not use an extension cord. To ensure proper ventilation for your refrigerator, allow for a 1.25 cm space on each side and at the top. Allow for a 5 cm space behind the refrigerator. If your refrigerator has an ice maker, allow extra space at the back for the water line connections. When installing your refrigerator next to a fixed wall, leave a 9.5 cm minimum space between the refrigerator and wall to allow the door to swing open. NOTE: This refrigerator is intended for use in a location where the temperature ranges from a minimum of 10°C to a maximum of 43°C. The preferred room temperature range for optimum performance, which reduces electricity usage and provides superior cooling, is between 15°C and 32°C. It is recommended that you do not install the refrigerator near a heat source, such as an oven or radiator. Failure to follow these instructions can result in death, fire, or electrical shock. IMPORTANT: Installation and the electrical connection must be carried out by a qualified technician according to the manufacturer’s instructions and in compliance with the local safety regulations. ■ ■ The refrigerator is designed to operate on a separate 220-240 Volt, 10 A, 50-60 Hz circuit. ■ ■ Make sure voltage specified on the rating plate corresponds to that of your home. ■ ■ It must be possible to disconnect the appliance from power supply by unplugging it or by means of a main two pole switch installed upstream of the socket. If supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. Before you move your refrigerator into its final location, it is important to make sure you have the proper electrical connection: Recommended Earthing Method 220-240 Volt 50 Hz, 220 Volt 60 Hz, or 230/240 Volt 50 Hz AC only 10 A fused and earthed electrical supply is required. ■ ■ 1,25 cm Type B Type E and F 9,5 cm Type I Type M Type G For Australia and New Zealand: Your new appliance has been especially manufactured to meet all Australian Standards and Conditions. Some notations in the installation instructions may refer to electrical requirements in other countries, so we draw your particular attention to these specific notes. Your appliance needs to be plugged into a 230/240 Volt 50 Hz AC only 10 A earthed socket. 9