AHI Carrier Catalog | Page 242

Options

Options No . Description Advantages Use 30HXC
COOLING
Low-temperature brine solution
6
Low-temperature glycol solution production down
to -10 ° C
Covers specific applications such as ice storage and industrial processes
090 , 110 , 130 , 155 , 175 , 200 , 230 , 260 , 310 ,
345 080-375
IP44C electrical protection level
20
Control box tightness reinforced
Permits unit installation in more severe environments
Tropicalisation
22
Unit control box suitable for tropical climates
Reduced relative humidity in the control boxes for
080-375
operation in tropical climates ( warm and humid )
Soft starter
25
Electronic compressor starter
Reduced compressor start-up current
200-375
Cu / Ni condensers
33
Condenser tubes and tubes sheets in 90-10
Allows applications with sea water
080-375
Copper / Nickel alloy
Cu / Ni condensers + Sakaphen
34A
Condenser tubes and tubes sheets in 90-10
Allows applications with sea water , improved
080-375
coated water boxes
Copper / Nickel alloy and Sakaphen treatment inside durability of water boxes
Unit supplied in two assembled parts
water boxes
51
Unit supplied in two assembled parts . The unit is
Facilitates installation in plant rooms with limited
equipped with flanges that allow disassembly of the access
unit on site .
080-375
460-3-60 power supply
60
Power supply of 460 V-3 ph-60 Hz
Permits unit connection to a power network with
080-375
specific characteristics
380-3-60 power supply
61
Power supply of 380 V-3 ph-60 Hz
Permits unit connection to a power network with
080-375 specific characteristics
Evaporator pump electrical power /
84
Unit equipped with an electrical power / control
Quick and easy installation
080-375
control circuit
circuit for single evaporator pumps
Dual evaporator pump electrical power / control circuit
84D
Unit equipped with an electrical power / control circuit for dual evaporator pumps
Quick and easy installation
080-375
Condenser pump electrical power /
84R
Unit equipped with an electrical power / control
Quick and easy installation
080-375
control circuit
circuit for single condenser pumps
Compressor suction valve
92
Valve set for the compressor suction side to isolate it
Simplified service and maintenance
080-375
in the refrigerant circuit .
Evaporator with one pass
100C
Evaporator with one pass on the water-side . Evaporator inlet and outlet on opposite sides .
Quick and easy installation . Reduced evaporator
080-375 pressure losses .
Condenser with one pass
102C
Condenser with one pass on the water-side .
Quick and easy installation . Reduced condenser
080-375
Condenser inlet and outlet on opposite sides .
pressure losses .
21 bar evaporator
104
Reinforced evaporator for extension of the
Covers applications with a high water column
080-375
maximum water-side service pressure to 21 bar
( high buildings )
21 bar condenser
104A
Reinforced condenser for extension of the
Covers applications with a high water column
080-375
maximum water-side service pressure to 21 bar
( high buildings )
Reversed evaporator water
107
Evaporator with reversed water inlet / outlet
Simplification of the water piping
080-375
connections
Reversed condenser water
107A
Condenser with reversed water inlet / outlet
Simplification of the water piping
080-375
connections
JBus / ModBus gateway
148B
Two-directional communications board , complies
Easy connection by communication bus to a
080-375
with JBus / ModBus protocol
building management system
BacNet gateway
148C
Two-directional communications board , complies
Easy connection by communication bus to a
080-375
with BacNet protocol
building management system
LON gateway
148D
Two-directional communications board , complies
Easy connection by communication bus to a
080-375
with LON protocol
building management system
High condensing temperature
150
Increased condenser leaving water tempe-rature up to 63 ° C . Control of the condenser leaving water
Allows applications with high condensing temperature ( for heat reclaim or dry cooler
080-375
High condensing temperature in non-reversible applications
Control for low condensing temperature systems
RS 485 communication interface
with open protocol Dual discharge valve installed with
three-way valve
Code compliance for Switzerland in addition to PED code
temperature .
applications )
150A
Operation in heat pump mode only with condenser
Allows applications with high condensing
080-375
leaving water temperature up to 63 ° C .
temperature ( for heat reclaim or dry cooler
applications )
152
Output signal ( 0-10 V ) to control the condenser
Used for applications with cold water at
080-375
water inlet valve
condenser inlet ( well water ). In this case the valve
controls the water entering temp . to maintain an
acceptable condensing pressure .
155
Additional RS 485 communication board
Communication via CCN protocol
080-375
194 Three-way valve upstream of the discharge valves on the evaporator and the oil separator
Vallve change and inspection facilitated without refrigerant loss . Complies with European
standard EN 378 / BGVD4 .
197
Additional tests on the water heat exchangers .
Conformance with Swiss regulations in addition
Additional supply of PED documents , supple-mentary to the PED code
certificates and test certificates .
080-190
080-375
Russian code compliance
199
GOST certification
Conformance with Russian regulations ( GOST )
080-375
Water connection kit for welded
266
Victaulic piping connections with welded joints .
Easy installation
080-375
evaporator connections
Water connection kit for welded
267
Victaulic piping connections with welded joints .
Easy installation
080-375
condenser connections
Water connection kit for flanged
268
Victaulic piping connections with flanged joints .
Easy installation
080-375
evaporator connections
Water connection kit for flanged
condenser connections
269
Victaulic piping connections with flanged joints .
Easy installation
080-375
242 C A R R I E R 2 0 1 6 / 2 0 1 7