AHI Carrier Catalog | Page 241

WATER-COOLED SCREW COMPRESSOR LIQUID CHILLERS 30HXC 080-375 Physical data 080 090 100 110 120 130 140 155 175 190 200 230 260 285 310 345 375 30HXC Cooling C1 Nominal capacity kW C1 EER kW/kW 5.03 4.79 4.82 4.60 4.87 4.72 4.74 4.57 4.68 4.73 4.74 4.74 4.46 4.77 4.76 4.56 4.66 C1 Eurovent Energy Class ESEER 312 B kW/kW B 348 375 B 413 C 450 B B 510 B 543 C 600 B 652 B 701 B 814 B 899 C 987 B 1109 1207 1302 B C B 5.56 5.41 5.31 5.28 5.23 5.21 5.17 4.85 5.03 4.97 5.08 5.06 5.01 5.11 5.49 5.39 5.34 Sound Power Level Standard Unit dB(A) 94 Operating weight kg 2274 2279 2302 2343 2615 2617 2702 2712 3083 3179 3873 4602 4656 4776 5477 5553 5721 Depth mm 2558 2558 2558 2565 3275 3275 3275 3275 3275 3275 3903 3924 3924 3924 4533 4533 4533 Length mm 980 Height mm 1800 1800 1800 1850 1816 1816 1816 1816 1940 1940 1980 2060 2060 2060 2112 2112 2112 94 94 94 94 97 98 100 101 101 99 101 102 102 103 104 104 Dimensions, standard unit 980 980 980 980 980 980 980 980 980 1015 1015 1015 1015 1015 1015 1015 Refrigerant R-134a Compressors 06N semi-hermetic twin-screw compressor Quantity - Circuit A 1 1 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 Quantity - Circuit B 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 2 2 Capacity control Pro-Dialog Plus control No. of control steps 6 6 6 6 6 6 6 8 8 8 8 10 10 10 Evaporator Shell and tube with internally finned copper tubes 5 5 6 6 6 6 8 8 8 6 6 6 8 8 8 8 8 8 Water connections 6 6 6 Victaulic Inlet/outlet in 4 4 5 4 5 5 5 5 Condenser Shell and tube with internally finned copper tubes Water connections Victaulic Inlet/outlet in 5 5 5 5 5 5 5 5 COOLING Seasonal Efficiency* 287 C1 Cooling mode conditions: Evaporator Water heat exchanger, entering/leaving temperature 12°C/7°C, fouling factor 0 m2 K/W. Condenser Water heat exchanger, entering/leaving temperature 30°C/35°C, fouling factor 0 m2 K/W. * In accordance with standard EN14511-3:2013 Weight shown is a guideline only. The dimensions shown are for the standard unit. For other unit types please refer to the dimensional drawings. HEATING HEATING Full loa d performances* Electrical data 30HXC 080 090 100 110 120 130 140 155 175 190 200 230 260 285 310 345 375 Power circuit Nominal power supply (Un)* V-ph-Hz Control circuit supply 400-3-50 ± 10% The control circuit is supplied via the factory-installed transformer Nominal current drawn* A 101 115 127 143 149 168 190 207 226 234 255 294 337 354 399 448 477 Maximum starting current*** A 181 206 223 249 267 298 333 355 382 442 841 978 1027 1200 1129 1184 1373 Circuit A** A - - - - - - - - - - 712 822 871 1028 844 871 1028 Circuit B** A - - - - - - - - - - 605 715 715 856 844 871 1028 A R R I E R 2 0 1 6 / 2 0 1 7 CONTROLS * Standard Eurovent conditions: Evaporator entering/leaving water temperature 12°C and 7°C. Condenser entering/leaving water temperature 30°C/35°C. ** Maximum unit operating current at maximum unit power input. *** Maximum instantaneous starting current (maximum operating current of the smallest compressor(s) + locked rotor current or reduced starting current of the largest compressor). C AIR TREATMENT Eurovent certified data 241