• CRADLE TO GRAVE
“ Depending on the explosive system and delivery configuration, inhibitors such as urea may be incorporated during manufacturing or introduced during the sensitisation process,” he said. However, he stressed that inhibitor concentrations must always be determined through site-specific testing and validation.
“ Site-specific reactivity assessments, inhibitor requirement determination and sleep-time validation remain essential to ensuring safe blasting performance,” he emphasised.
While inhibited emulsions are designed to slow reaction rates and provide a larger safety window, they do not eliminate the underlying chemistry.“ They therefore complement, rather than replace, rigorous testing and disciplined operating procedures,” he said.
He noted that elevated temperatures can also affect explosive performance.“ Certain explosive components may begin to soften at temperatures of around 70 ° C, increasing the risk of degradation or premature initiation,” he said.“ Both electronic and non-electric initiation systems may also be adversely affected if conditions are not properly understood and controlled.”
He added that ammonium nitrate-based bulk explosives at prolonged exposure to elevated temperatures can increase the likelihood of decomposition or ignition, particularly where reactive ground conditions are present.
Mine life: Continuous validation According to Hariparsad, effective reactive ground management is an ongoing process that must evolve as mining progresses.
“ Reactive ground testing should begin as soon as reactivity is suspected and continue throughout the life of the operation,” he said.“ As mining advances into new geological domains, changing ground conditions may alter a site’ s reactivity profile, requiring explosive formulations, inhibitor levels and allowable sleep times to be continuously validated.”
Where uncertainty exists regarding hole temperature, reactive ground potential, product suitability or allowable sleep time, BME advocates a stop-work approach until risks have been reassessed and appropriate controls implemented.
“ Safe blasting also depends on maintaining confidence in the predictability of the entire blasting process,” he said.
He stressed that personnel should never attempt to remove explosives from a reacting blast hole or recharge affected holes.“ Once a reaction has started, exclusion zones and emergency procedures must be implemented immediately,” he said.
Drawing on global experience and best practice, BME continues to support mining operations through scientific testing, product development and technical expertise.“ This facilitates the management of increasingly complex blasting environments safely and effectively,” Hariparsad concluded. •
Reactive ground often develops without obvious warning signs, which is why it is frequently referred to as the industry’ s‘ silent killer’.
High-temperature mining environments require specialised explosives and rigorous monitoring to minimise risk and ensure operational safety.
About Hot holes and reactive ground: practical risk indicators Victor Krause, Reactive Ground specialist at BME, said blast holes are generally classified as hot holes when temperatures exceed 40 ° C or when monitoring records a temperature increase of 3 ° C or more during observation.
“ Elevated temperatures may result from coal seam fires, sulphide oxidation, geothermal gradients and other geological factors,” he said.“ Coal seam fires can generate temperatures exceeding 600 ° C and, during active combustion, more than 1 000 ° C.” Many operations therefore employ formal hot-hole classification systems linked to defined control measures. He said that while thresholds vary according to site-specific risk assessments and product approvals, holes above 40 ° C typically require additional controls.“ Significantly higher temperatures may require cooling interventions or abandonment pending further assessment,” he said.
Blast-hole liners or sleeves may also be used in some applications to create a barrier between explosives and hot or reactive ground.“ However, their effectiveness depends on factors such as temperature, exposure time, liner integrity, loading method and explosive formulation, making site-specific risk assessment essential,” he said.
About A hidden risk Krause cautioned that temperature alone is not always a reliable indicator of reactive ground.“ Some of the most severe reactions occur in blast holes showing little or no evidence of elevated temperatures before charging,” he said. Potential warning signs include sulphide-bearing sediments, acidic conditions, equipment corrosion, smoke, fumes, bubbling, product movement, discolouration, unusual odours and unexplained increases in hole temperature.
He illustrated the risk with a case study in which BME monitored emulsion-loaded soil samples from a coal mine.“ Temperatures increased gradually from 32 ° C to 178 ° C over several days before rapidly entering thermal runaway. Within just 19 minutes, temperatures escalated to approximately 800 ° C and the sample ignited,” he said.
In reactive-ground environments, operating procedures may require loaded holes to remain unstemmed during monitoring periods to allow warning signs to be detected before conditions escalate.“ Once a reaction has started, personnel should never attempt to remove explosives or recharge the blast hole,” he said.“ Instead, exclusion zones and site-specific emergency procedures must be implemented immediately.”
36 • African Mining • October 2026 www. africanmining. co. za