African Mining July 2025 | Page 17

COUNTRY IN FOCUS •
“ The final design allowed us the opportunity to provide drainage infrastructure to take the dam to 60 metres,” he explained.“ The penstock towers and the internal main drain were included to allow a second phase of elevation; these elements would have been very difficult to retrofit at the point in the TSF life when it had reached 30 metres in height.”
The main drains are strategically placed vertically below the crest of the full level, aiding the drawdown of the outer shell’ s phreatic surface to reduce the risk of failure. The storage capacity of the facility is substantial, as the mine is expected to generate production of 466, 000 tonnes per month over a 20-year deposition period.
The client also wanted to duplicate critical infrastructure, so the design provided two penstock towers and pipelines discharging separately into the two-compartment silt trap. This duplication both allows one component to be taken out of commission to enable cleaning of the associated silt trap compartment, and to provide redundancy should one system become inoperable. The towers have been designed with three outlet heights which, when combined with the ringing up method, allow decanting all the way to 60m.
Robertshaw highlighted the value of taking a developmental approach on the Mimosa TSF project, which led to a heightened sense of achievement among everyone who contributed. While meeting the highest standards of TSF design and construction, the project had also leveraged its local economic impact through a responsible mining approach. •
Impala’ s philosophy to duplicate critical infrastructure was reflected in the choice to provide two penstock towers and pipelines discharging separately into the twocompartment silt trap, allowing one component to be taken out of commission to enable cleaning of the associated silt trap compartment, and to provide redundancy www. africanmining. co. za African Mining Publication African Mining African Mining • July 2025 • 15