ZEMCH 2019 International Conference Proceedings April.2020 | Page 413

Experimental Performance of an Advanced Air Type  Photovoltaic‐Thermal (PVT) Collector with Direct  Expansion Air Handling Unit (AHU)  Jin‐Hee Kim  1 , Sang‐Myung Kim  2  and Jun‐Tae Kim  3, *      3   *  1 2 Green Energy Technology Research Center, Kongju National University; [email protected]  Graduate School of Energy System Engineering, Kongju National University; [email protected]  Department of Architectural Engineering, Kongju National Univiersity; [email protected]  Correspondence: [email protected]; Tel.: +82‐41‐521‐9333  Abstract:  Photovoltaic  thermal  (PVT)  systems  utilize  heat  which  is  exhausted  from  Building  Integrated Photovoltaic (BIPV) modules, occurring together with electricity generation, for domestic  hot water and space heating. In other words, electrical efficiency is enhanced through BIPV arrays,  and the resulting waste heat is reused as a source of energy for buildings. By generating both thermal  and electrical energy at the same time, PVT systems can improve the utilization of solar energy while  enhancing the energy performance of buildings. In order to obtain better performance of air‐type PVT  collectors, it is necessary to extract the hot or warm heat from the PV module, which then decreases  its temperature. The thermal and electrical performance of an air‐type PVT collector depends on their  design  affected  airflow  and  heat  transfer.  Moreover,  performances  of  the  PVT  collector  can  differ  according to the coupled facility in building. In this paper, the thermal and electrical performances of  an advanced air‐type PVT collector with a direct expansion Air Handling Unit (AHU) were analyzed  experimentally. For this study, a prototype of an advanced air‐type PVT collector was developed and  made. Furthermore, a direct expansion AHU with heat recovery exchanger (HRX) was designed and  built. The advanced PVT collectors with capacity of 740Wp were installed in an experimental house  and  were  coupled  to  a  direct  expansion  AHU  system  with  airflows  of  maximum  700CMH.  Their  operation  conditions  were  carefully  considered  and  controlled  to  obtain  better  performance  of  the  advanced air‐type PVT collectors.    Keywords:  BIPVT  (Building‐integrated  photovoltaic);  Air‐type  PVT  collector;  AHU  (Air‐handling  unit); Mock‐up experiment; Thermal & Electrical efficiency                  Experimental Performance of an Advanced Air Type Photovoltaic-Thermal (PVT) Collector with Direct Expansion Air Handling Unit (AHU) 402