Based on the experimental results and the analysis results in this study, additional device configuration  is needed, and the efficiency should be equal to or higher than that of the seawater desalination system using  reverse osmosis through later heat pump cycle and flow control of internal fluid.  Author Contributions: “conceptualization, Young‐Chull Ahn.; methodology, Young‐Chull Ahn.; validation, Soo‐ Kwang Yang and Dong‐In Kang.; formal analysis, Young‐Chull Ahn and Soo‐Kwang Yang.; investigation, Yu‐Jung  Ryu;  writing—original  draft  preparation,  Soo‐Kwang  Yang.;  writing—review  and  editing,  Young‐Chull  Ahn.;  supervision, Young‐Chull Ahn.; project administration, Young‐Chull Ahn.”  Funding: Please add: “This research was supported by the National Research Foundation of Korea(NRF) grant  funded by the Korea government(MSIT)(No.2018R1A2B6004137)  References  1. 2. 3. 4. 5. 6. 7. Water Information Portal.Trends and Implications of Global Seawater Desalination.2016  In‐Soo Kim,    Moon‐Hyun Hwang, Chang‐Gyu Choi, Sung‐Jo Kim, Seung‐Ho Kook, Do‐Sun Han, Jin‐Woo  Lee. A Study on the Development of High‐efficiency Low‐Energy Seawater Desalination Plant Technology  using Renewable Energy. Gwangju Institute of Science and Technology. 2016  Kesieme U.K, Milne N, Aral H, Cheng C.Y, Duke M. Economic analysis of desalination technologies in the  context of carbon pricing and opportunities for membrane distillation. Desalination, vol.323, pp66‐74. 2013  Seung‐gwan Hong , Sang‐ho Lee, Joon‐ha Kim, Jung‐hoon Kim,Young‐gil Ju. Evolution of Reverse Osmosis  Process for Green Future. Industrial Chemistry Prospect. 2011,Vol. 14, No. 6.  Young‐Hwang Hwang, Young‐In Kim, Moon‐Hee Jang. Optimization of SMART Desalination Plant. Korea  Atomic Energy Research Institute. Technical Report. 2002  Chi‐Sung Song. Energy Consumption of Evaporative Desalination Plant. Korean Society of Marine Engineers.  2014. Vol.38 (9)  Jurn Hur, Suk‐Jong Lee, Jae‐Yong Sung, Myeong‐Ho Lee, Jai‐Dong Yoon. Performance Test of Pressure and  Flow  Rate  in  a  Hot  Water  Heating  System  with  3  Way  Valves  for  Flow  Bypass.  Korea  Journal  of  Air‐ Conditioning and Refrigeration Engineering. 2007. Vol.19, pp269‐274.    © 2019 by the authors. Submitted for possible open access publication under the terms  and  conditions  of  the  Creative  Commons  Attribution  (CC  BY)  license    (http://creativecommons.org/licenses/by/4.0/).      395 ZEMCH 2019 International Conference l Seoul, Korea