ZEMCH 2019 International Conference Proceedings April.2020 | Page 128
2.2 The windows
The characteristics of the windows measured in the experiment are shown in Table 1.
Table 1. Characteristics of the measured windows.
Code
ET‐PI‐01
T‐PI‐01
RA‐PI‐01
Floor/Building
1º /
Orientation
SW 260º
Room Window
Area area
24.10 m2 3.10 m2
Del Moral
Window type
Single‐glazed in
woodwork with full
wooden leaf enclosure
ET‐PI‐04
T‐PI‐04
RA‐PI‐04
4º /
Los
Manzanos SW 260º 13.11 m2 4.18 m2
ET‐PI‐05
T‐PI‐05
RA‐PI‐05
5º /
Los
Manzanos SW 260º 13.11 m2 4.18 m2
ET‐PI‐07
T‐PI‐07
RA‐PI‐07
7º /
Los
Manzanos SW 260º 13.11 m2 4.18 m2
Aluminum frame.
Single‐glazed sliding
system with 6mm
laminated glass. Upper
part is sliding, lower
part is fixed, central
aluminum pipe.
.
Aluminum profile
Double‐glazed sliding
system, both sheets
with 6mm laminated
glass.
Upper part is sliding,
lower part is fixed,
central aluminum pipe.
.
Aluminum carpentry
on all edges)
8mm tempered glass.
Upper part is sliding,
lower part is fixed,
central aluminum pipe.
2.3. Thermal stress Analysis
According to ISO 7933: 2004 Ergonomics of the thermal environment — Analytical determination
and interpretation of heat stress used calculation of the predicted heat strain.
• The measurement was taken after 30 minutes of turning on the equipment in order to stabilizes the
sensor.
• The natural temperature sensor of the wet bulb was covered with a wick moistened with distilled
water.
• The measurement was taken for 15 minutes approximately 170 centimeters from the ground.
• Every 05 minutes the data provided by the team was recorded, this at different levels.
117
ZEMCH 2019 International Conference l Seoul, Korea