ZEMCH 2019 International Conference Proceedings April.2020 | Page 423

Table 2. Error record  Parameter  Grid side  PCS  Battery  Common  Explanation  Over current  Grid over current protection  Current unbalance  Grid current unbalance protection  Overvoltage  Grid Over voltage protection  Low voltage  Grid Low voltage protection  High frequency  Grid High frequency protection  Low frequency  Grid current unbalance protection  System fault  Stop on system fault  FAN fault  FAN fault protection  IGBT short circuit  IGBT fault protection  IGBT overheating  IGBT overheating protection  Filter overheating  AC/DC filter overheating protection  E‐stop  Emergency button  System fault  Stop on system fault  Overcharge protection  Protection against overcharging beyond the  protective voltage  Over discharge protection  Protection against discharging beyond the  protective voltage  Overcurrent Shutdown  Overcurrent protection due to external device Short circuit protection  Protection against external load short circuit  Overheat protection  Protection against overheating    Communication fault  Alarm service provided    3.3. Communication Flow between PMS and EMS    A  socket  client  and  a  server  were  designed  to  implement  communication  between  PMS  and  storage and between EMS and storage for remote monitoring and control of ESS. The flow chart is as  follows:    Database  queries  for  data  transmission  and  reception  via  direct  IP  and  port  forwarding  are  vulnerable to security issues. Therefore, data collection and facility remote control are implemented by  applying socket packetization and transmission technology.    Information collected about all ESS operating facilities by PMS is transmitted to socket server in  WAS installed externally through “socket client”. The socket server that has received sockets from PMS  analyzes the packets and stores them in DB Storage.    EMS performs monitoring by processing real‐time data and cumulative data based on data stored  in DB, and by using socket client manufactured for control in WAS to remotely control ESS in EMS.  The WAS socket client sends a facility control command socket to the PMS socket server and saves  the operation history by transmitting the transmission details to DB Storage. The PMS socket server  receiving the operation/control command from the EMS analyzes the socket packet and operates and  controls the ESS based on the analysis results.      Developed of Stand-alone PMS and Remote Control/Monitoring EMS for Safe Operation of ESS 412