York HVAC Catalogue 2018 EN 2019 EN | Page 46

YMWA / YMRA Water-cooled cooling only, remote condenser and heat pump scroll compressor chiller Cooling capacities from 21 kW to 193 kW Same cabinet w/o or with factory mounted hydrokit (one or two pumps). More compact and slim. Features • Scroll compressors (single or tandem) • Higher EER and COP • 2 different frames / configurations: · 1 compressor / 1 circuit up to 45 kW · 2 compressors / 1 circuit from 50 to 190 kW • Reduced refrigerant charge • Condensing pressure control • “Plug and Play” units Available versions 14 available YMWA sizes in three versions: 1) YMWA-CO : Cooling only 2) YMRA : Remote condenser 3) YMWA-HP : Reversible heat pump Nominal capacity and technical data YMWA-CO 0020 0025 0030 Cooling Capacity (kW) EER SEER ŋs, c Length / Width / Height (mm) Operating weight (kg) 21.2 4.58 5.575 215 26.2 4.54 5.6 216 162 182 31.1 34.8 4.46 4.53 5.45 5.5 210 212 821 / 455 / 1350 179 185 YMRA 0020 0025 21.2 26.2 144 164 0020 0025 0030 20.8 23.7 4.45 3.88 5.03 193 26 28.9 4.47 3.85 5.03 193 165 187 30.1 34 33.6 38.5 4.28 4.35 3.73 3.79 4.85 4.95 186 190 821 / 455 / 1350 184 190 Cooling Capacity (kW) Length / Width / Height (mm) Operating weight (kg) YMWA-HP Cooling Capacity (kW) Heating Capacity (kW) EER COP SCOP ŋs, h Length / Width / Height (mm) Operating weight (kg) 0030 0035 0035 31.1 34.8 821 / 455 / 1350 166 166 0035 0040 0045 0050 0060 0075 0090 0120 0150 0170 0190 39.2 4.48 5.35 206 46.6 4.57 5.825 225 50.9 4.29 6.125 237 61.1 4.48 6.375 247 77.3 4.48 5.95 230 91.1 118.4 4.38 4.46 6.7 5.9 260 228 1210 / 850 / 1500 411 597 147.1 4.46 6.125 237 170 4.50 6.075 235 192.7 4.51 6.2 240 666 701 745 0090 0120 0150 0170 0190 91.1 118.4 1210 / 850 / 1500 376 558 147.1 170 192.7 612 643 674 191 214 352 371 392 0040 0045 0050 0060 0075 39.2 46.6 50.9 61.1 77.3 172 172 332 344 365 0040 0045 0050 0060 0075 0090 0120 0150 0170 0190 38.1 42.9 4.33 3.77 4.88 187 45.5 51.2 4.39 3.85 4.74 182 49.9 57.7 4.15 3.83 4.99 192 58.9 68.2 4.24 3.81 4.94 190 76.1 86.3 4.36 3.92 5,22 201 144.3 164.2 4.33 3.95 5.27 203 165.7 190.1 4.34 3.93 5.23 201 185.4 212.3 4.28 3.93 5.22 201 195 219 360 379 403 88.6 114.9 102.2 132 4.20 4.26 3.89 3.92 5.09 5.17 196 199 1210 / 850 / 1500 422 610 683 718 762 Net values at Eurovent nominal conditions: YMWA-CO: Standard Eurovent LCP/W/AC conditions in cooling mode: evaporator EWT/LWT 12°C/7°C, condenser EWT/LWT 30°C/35°C YMRA: Evaporator EWT/LWT 12°C/7°C, condensing temperature 40°C YMWA-HP: Standard Eurovent LCP/W/AC conditions in cooling mode: evaporator EWT/LWT 12°C/7°C, condenser EWT/LWT 30°C/35°C YMWA-HP: Standard Eurovent LCP/W/AC conditions in heating mode: evaporator EWT/LWT 10°C, condenser EWT/LWT 40°C/45°C Ecodesign figures are calculated following variable outlet approach. SEER and SCOP calculated according to EN14511 and EN14825 ηs calculated according to Ecodesign regulation for chillers comfort cooling and heating (813/2013, 2016/2281). For other Ecodesign calculations, please contact your JCI representative. The above data is based on Johnson Control’s selection software YORKworks 18.06. Please refer to the latest version of the software for specific projects 46