York HVAC Catalogue 2018 EN 2019 EN | Page 35
YORK ® AIR-CONDITIONING PRODUCTS
Air-cooled VSD screw chiller
YVAA 0588 to 1843
Application flexibility (*) example of selections
YVAA
Cooling capacity (kW)
EER
SEER
ŋs, c
Sound power level (dBA)
YVAA
Cooling capacity (kW)
EER
SEER
ŋs, c
Sound power level (dBA)
YVAA
Cooling capacity (kW)
EER
SEER
ŋs, c
Sound power level (dBA)
0588
569
3.24
4.32
170
98 0643
573
3.07
4.27
168
96 0665
588
3.17
4.40
173
97 0688
639
3.23
4.58
180
98 0700
614
2.83
4.15
163
95 0743
658
3.13
4.41
173
97 0765
649
3.16
4.63
182
96 0788
738
3.15
4.73
186
98 0843
748
2.90
4.50
177
98 0865
768
3.14
4.73
186
98 0888
808
3.17
4.80
189
98 0943
812
2.99
4.61
181
99 0960
832
3.06
4.48
176
98 0963
867
3.07
4.71
186
99 0965
898
3.09
4.87
192
99 0988
933
3.15
5.00
197
100 1015
948
3.13
4.85
191
99 1065
971
3.02
4.74
187
100 1088
997
3.15
4.97
196
100 1093
964
2.92
4.61
181
100 1143
1002
2.95
4.68
184
99 1173
1008
2.92
4.61
182
100 1188
1022
3.18
5.02
198
100 1193
1017
3.07
4.78
188
100 1215
1047
3.11
4.90
193
100
1288
1118
3.23
4.84
190
100 1315
1077
3.17
4.72
186
100 1343
1221
3.11
4.68
184
101 1388
1260
3.11
4.63
182
100 1443
1455
2.92
4.56
179
101 1488
1237
3.17
4.87
192
101 1515
1346
3.14
4.83
190
102 1543
1371
3.16
4.86
192
102 1650
1385
3.08
4.73
186
103 1665
1390
3.04
4.62
182
102 1693
1545
3.07
4.75
187
102 1700
1569
2.91
4.57
180
103 1843
1654
2.96
4.67
184
105
Net values at Eurovent nominal conditions for models using R134a: Cooling capacities in kW given for 7°C water leaving temperature ∆t 5°C and 35°C ambient temperature.
SEER calculated according to EN14511 and EN14825.
ηs calculated according to Ecodesign regulation for chillers comfort cooling (2016/2281). For other Ecodesign calculations, please contact your JCI representative.
(*) YVAA is a tailor and tune chiller. Its performance will be factory-adjusted to match the exact site requirements based on the specific project operating conditions.
The table above shows only a representative sample of performance points based on generic project operating conditions working with R134a refrigerant.
For R513a information contact your JCI Representative.
For tailored and tuned performance based on your specific project requirements, and for more information, please contact your Johnson Controls representative.
The above data is based on Johnson Control’s selection software YORKworks 18.06. Please refer to the latest version of the software for specific projects.
Technical data
YVAA
Length
Dimensions
Width
Height
Operating weight kg
Refrigerant charge kg
mm
mm
mm
YVAA
Length
Dimensions
Width
Height
Operating weight kg
Refrigerant charge kg
mm
mm
mm
YVAA
Length
Dimensions
Width
Height
Operating weight kg
Refrigerant charge kg
mm
mm
mm
0588
7397
0643
6274
0665
7397
0688
8514
0700
5741
0743
7397
0765
7397 0788
8514 0843
7397 0865
8514 0888
9631 0943
8514
2241
2401
7554
204 6208
150 6551
164 7012
189 6977
186 6589
160 7668
204 8011
218 6793
182 8100
216 8445
228 7151
192 0960
7397 0963
8514 0965
8514 0988
9631 1015
9631 1065
10748 1093
9631 1143
9631 1173
10748 1188
11865 1193
10748 1215
11865
7412
228 8314
240 8651
242 8996
246 9201
261 9007
248 1088
10748
2241
2401
9546
268 8665
243 9362
268 8612
264 9891
277 9704
282 10049
286
1288
12987 1315
11864 1343
11864 1388
14104 1443
11864 1488
15222 1543
14104 1650
11864 1665
15222 1693
15222 1700
11865 1843
15222
12435
360 12086
353 11169
302 12939
378 10558
365 13284
390 1515
14104
2241
2401
11249
382 12802
336 11287
358 14066
404 13149
350 12951
368 14066
404
Manufacturer reserves the rights to change specifications without prior notice.
35