York HVAC Catalogue 2018 EN 2019 EN | Page 35

YORK ® AIR-CONDITIONING PRODUCTS Air-cooled VSD screw chiller YVAA 0588 to 1843 Application flexibility (*) example of selections YVAA Cooling capacity (kW) EER SEER ŋs, c Sound power level (dBA) YVAA Cooling capacity (kW) EER SEER ŋs, c Sound power level (dBA) YVAA Cooling capacity (kW) EER SEER ŋs, c Sound power level (dBA) 0588 569 3.24 4.32 170 98 0643 573 3.07 4.27 168 96 0665 588 3.17 4.40 173 97 0688 639 3.23 4.58 180 98 0700 614 2.83 4.15 163 95 0743 658 3.13 4.41 173 97 0765 649 3.16 4.63 182 96 0788 738 3.15 4.73 186 98 0843 748 2.90 4.50 177 98 0865 768 3.14 4.73 186 98 0888 808 3.17 4.80 189 98 0943 812 2.99 4.61 181 99 0960 832 3.06 4.48 176 98 0963 867 3.07 4.71 186 99 0965 898 3.09 4.87 192 99 0988 933 3.15 5.00 197 100 1015 948 3.13 4.85 191 99 1065 971 3.02 4.74 187 100 1088 997 3.15 4.97 196 100 1093 964 2.92 4.61 181 100 1143 1002 2.95 4.68 184 99 1173 1008 2.92 4.61 182 100 1188 1022 3.18 5.02 198 100 1193 1017 3.07 4.78 188 100 1215 1047 3.11 4.90 193 100 1288 1118 3.23 4.84 190 100 1315 1077 3.17 4.72 186 100 1343 1221 3.11 4.68 184 101 1388 1260 3.11 4.63 182 100 1443 1455 2.92 4.56 179 101 1488 1237 3.17 4.87 192 101 1515 1346 3.14 4.83 190 102 1543 1371 3.16 4.86 192 102 1650 1385 3.08 4.73 186 103 1665 1390 3.04 4.62 182 102 1693 1545 3.07 4.75 187 102 1700 1569 2.91 4.57 180 103 1843 1654 2.96 4.67 184 105 Net values at Eurovent nominal conditions for models using R134a: Cooling capacities in kW given for 7°C water leaving temperature ∆t 5°C and 35°C ambient temperature. SEER calculated according to EN14511 and EN14825. ηs calculated according to Ecodesign regulation for chillers comfort cooling (2016/2281). For other Ecodesign calculations, please contact your JCI representative. (*) YVAA is a tailor and tune chiller. Its performance will be factory-adjusted to match the exact site requirements based on the specific project operating conditions. The table above shows only a representative sample of performance points based on generic project operating conditions working with R134a refrigerant. For R513a information contact your JCI Representative. For tailored and tuned performance based on your specific project requirements, and for more information, please contact your Johnson Controls representative. The above data is based on Johnson Control’s selection software YORKworks 18.06. Please refer to the latest version of the software for specific projects. Technical data YVAA Length Dimensions Width Height Operating weight kg Refrigerant charge kg mm mm mm YVAA Length Dimensions Width Height Operating weight kg Refrigerant charge kg mm mm mm YVAA Length Dimensions Width Height Operating weight kg Refrigerant charge kg mm mm mm 0588 7397 0643 6274 0665 7397 0688 8514 0700 5741 0743 7397 0765 7397 0788 8514 0843 7397 0865 8514 0888 9631 0943 8514 2241 2401 7554 204 6208 150 6551 164 7012 189 6977 186 6589 160 7668 204 8011 218 6793 182 8100 216 8445 228 7151 192 0960 7397 0963 8514 0965 8514 0988 9631 1015 9631 1065 10748 1093 9631 1143 9631 1173 10748 1188 11865 1193 10748 1215 11865 7412 228 8314 240 8651 242 8996 246 9201 261 9007 248 1088 10748 2241 2401 9546 268 8665 243 9362 268 8612 264 9891 277 9704 282 10049 286 1288 12987 1315 11864 1343 11864 1388 14104 1443 11864 1488 15222 1543 14104 1650 11864 1665 15222 1693 15222 1700 11865 1843 15222 12435 360 12086 353 11169 302 12939 378 10558 365 13284 390 1515 14104 2241 2401 11249 382 12802 336 11287 358 14066 404 13149 350 12951 368 14066 404 Manufacturer reserves the rights to change specifications without prior notice. 35