York HVAC Catalogue 2018 EN 2019 EN | Page 175
YORK ® AIR-CONDITIONING PRODUCTS
ACTIVA Rooftop
ARC-ARG-ARH-ARD 045 to 090 BB
Technical features
Cooling only models
Net cooling capacities
Power input
SEER
ηs,c
Working range (full load / partial load) *
Heat pump models
Net cooling capacities
Power input in cooling
Heating capacities (1)
Power input in heating
SCOP
ηs,h
Working range (full load / partial load) *
Cooling only + Gas heating models
Net cooling capacities
Cooling power input
Standard Heating capacities (1)
Natural gas 2ND-H, G20
High Heating capacities (1)
Natural gas 2ND-H, G20
Working range (full load / partial load) **
Heat pump + Gas heating models
Net cooling capacities
Cooling power input
Heating capacities (1)
Power input in heating
Standard Heating capacities (1)
Natural gas 2ND-H, G20
High Heating capacities (1)
Natural gas 2ND-H, G20
Working range (full load / partial load) **
Common characteristics
Power supply
Main switch
Main cable
Cable to thermostat
Number of circuits / Compressor type
Airflow
Evaporator fan
at nominal airflow Power input
Height
Nett dimensions Length
Depth
Nett weight ARC / ARG
Nett weight ARH / ARD
ARC 045 BB
48
15.0
3.03
118.1
kW
kW
ARC 060 BB
ARC 075 BB
62
75
20.9
26.0
3,00
3.01
116.9
117.1
7°C ~ 46°C / -10°C ~ 52°C
ARH 060 BB
ARH 075 BB
62
72
20.0
28.0
58.0
71.7
19.0
27.0
3.10
3.05
121.0
119.1
-10°C ~ 46°C / -10°C ~ 52°C
ARG 060 BB
ARG 075 BB
62
75
20.9
26.0
76.0
76.0
8.60
8.60
90.0
90.0
9.80
9.80
-15°C ~ 46°C / -15°C ~ 52°C
ARD 060 BB
ARD 075 BB
62
72
20.0
28.0
58.0
71.7
19.0
27.0
76.0
76.0
8.60
8.60
90.0
90.0
9.80
9.80
-15°C ~ 46°C / -15°C ~ 52°C
°C
ARH 045 BB
48
17.0
45.2
16.0
3.19
124.6
kW
kW
kW
kW
°C
ARG 045 BB
48
15.0
76.0
8.60
90.0
9.80
kW
kW
kW
m 3 /h
kW
m 3 /h
°C
ARD 045 BB
48
17.0
45.2
16.0
76.0
8.60
90.0
9.80
kW
kW
kW
kW
kW
m 3 /h
kW
m 3 /h
°C
ARC 090 BB
83
30.0
3.01
117.2
ARH 090 BB
84
36.0
86.5
33.0
3.15
123.0
ARG 090 BB
83
30.0
76.0
8.60
90.0
9.80
ARD 090 BB
84
36.0
86.5
33.0
76.0
8.60
90.0
9.80
400V/3 + N/ 50Hz
A
Nbr. x mm 2
Nbr. x mm 2
50
5 x 10
63
5 x 16
80
5 x 25
10 x 0.22
1 (tandem) / 2 x scroll
m 3 /h
kW
mm
mm
mm
kg
kg
80
5 x 25
8 500
3
1 316
3 180
2 337
900 / 1 010
930 / 1 040
2 (tandem) / 4 x scroll
13 500
16 000
5.5
7.5
1 367
1 367
3 750
3 750
2 337
2 337
1 118 / 1 228
1 142 / 1 252
1 145 / 1 255
1 220 / 1 330
11 500
4
1 316
3 180
2 337
945 / 1 055
985 / 1 095
All the data are at EUROVENT conditions with 400V/3+N/50Hz.
Cooling : Entering indoor coil temp. 27°C / 19°C WB and outdoor temperature 35°C - Heating : Entering indoor coil temp. 20°C and outdoor temperature 7°C / 6°C WB
(1) Add indoor fan motor consumption to know total heating capacity.
* With Premium kit (full load / partial load): -10°C ~ 50°C / -10°C ~ 52°C
** With Premium kit (full load / partial load): -20°C ~ 50°C / -20°C ~ 52°C
Codes
Cooling only models
Heat pump models
Cooling only + Gas heating models
Heat pump + Gas heating models
ARC 045 BB
S661752149
ARH 045 BB
S661752147
ARG 045 BB
S661752146
ARD 045 BB
S661752148
ARC 060 BB
S661752165
ARH 060 BB
S661752167
ARG 060 BB
S661752166
ARD 060 BB
S661752168
ARC 075 BB
S661752175
ARH 075 BB
S661752177
ARG 075 BB
S661752176
ARD 075 BB
S661752178
Thermostat
to be ordered separately
DPC-1
Manufacturer reserves the rights to change specifications without prior notice.
175
ARC 090 BB
S661752195
ARH 090 BB
S661752197
ARG 090 BB
S661752196
ARD 090 BB
S661752198